13 Technical Data
General data
Rated supply voltage:
24 V DC (voltage tolerance 19.2 V DC to
30 V DC according to EN 61131-2)
Maximum interruption time of supply voltage:
≤
10 ms (EN 61131-2)
Power consumption:
9.6 W (400 mA at 24 V DC)
Inrush current:
max. 5.6 A (with limitation of current)
Safety class:
III in accordance with EN 61131-2 and EN 50178
Environmental conditions
Operating temperature:
0 °C to 50 °C (32 °F to 122 °F)
Storage temperature:
-20 °C to +70 °C (-4 °F to 158 °F)
Relative humidity (non-condensing):
5 % to 95 %
Vibration resistance (operation):
(IEC 60068-2-6)
10 Hz
≤
f
<
57 Hz with 0.15 mm (0.0059 in)
9 Hz
≤
f
<
150 Hz with 2 g (0.0044 pound)
Shock resistance (operation):
25 g / 11 ms (IEC 60068-2-27)
Housing
Construction
Double-walled ABS housing
Withstands grease, oil, lubricants, alcohol, etc.
Flammability
class
UL 94-V0
Dimensions:
Diameter:
250 mm / 9.84 in
Total height incl. handle:
114 mm / 4.49 in
Protection degree:
IP65
Weight:
1250g / 2.8 pound (with E-Stop, with key switch,
without handwheel, without override potentiome-
ter and without cable)
Display
Type:
Graphics-capable color TFT LC display
Size:
6,5“ (132 x 98 mm)
Resolution:
VGA 640 x 480 pixels
Representation:
65536 colors
Background lighting:
2 CCFT cold cathode tubes,
lifetime 50,000 hours at 25°C in continous opera-
tion
Touch
screen:
Analog-resistive
Keypad:
- Membrane keypad with tactile feedback
- Keys laid out for thumb operation
- Left / right-hand operation
- Customer-specific keypad possible
- maximum 64 keys
- 4 status LEDs (maximum 12 LEDs)
Operating elements – standard:
Two 3-position enabling switches, twin circuit –
external connection
Emergency stop switch, twin circuit – external
connection
Operating elements – optional:
One location (middle) for:
Electronic handwheel – internal connection
3 axis joystick – internal connection
One location (left) for:
Override potentiometer – internal connection
Illuminated push-button: momentary action –
internal connection