Maximum interruption time of supply voltage:
≤
10 ms (following EN 61131)
Power consumption:
10.8 W (600 mA at 18 V DC, 450 mA at
24 V DC)
Inrush current:
max. 5.6 A (with limitation of current)
Safety class:
III in accordance with EN 61131-2 and
EN 50178
10.4.8.2
Environmental conditions
Operating temperature:
0 °C to 50 °C (32 °F to 122 °F)
Storage temperature:
-20 °C to +70 °C (-4 °F to 158 °F)
Relative humidity (non-condensing):
5 % to 95 %
Vibration resistance (operation):
(IEC 60068-2-6)
5 Hz
≤
f < 9 Hz with 7 mm (0.276 in)
9 Hz
≤
f < 150 Hz with 2 g (0.0044 pound)
Shock resistance (operation):
15 g (0.033 pound) / 11 ms (IEC 60068-2-27)
10.4.8.3
Housing
Construction:
ABS housing
Withstands grease, oil, lubricants, alcohol, etc.
Flammability class: UL94-V0
Dimensions:
Width: 160 mm (6.299 in)
Height: 140 mm (5.512 in)
Depth: 70 mm (2.756 in)
Protection degree:
IP65
Weight:
500 g (1.1 pound)
Display:
Status LEDs
10.4.8.4
Accessories
Intermediate cable:
Connection box to connection cable
KeTop IC220: 2 m / 6.56 ft
KeTop IC240: 4 m / 13.12 ft
Download cable:
KeTop XD040:
4 m / 13.12 ft. For downloading software and
for debugging via S2.
DIN Rail Holder Mounting Set
KeTop DR200:
For mounting on the rearside of a KeTop CB2xx
gatewaybox.
Strapping plug:
KeTop BC001:
Serves for bridging the emergency stop circuits
if the KeTop is unplugged.
10.5 Connection Cable KeTop TTxxx
The standard KeTop handheld terminals are available with the following ca-
bles:
●
KeTop TT025 (2.5 m / 8.2023 ft)