10.4.1
Construction
Fig.10-14:
View and device description of the Gateway box
1
... Status and error LEDs
2
... PG gland (M20) for voltage supply, en-
abling switch and emergency stop
3
... PG gland (M16) for separate functional
ground (status as supplied with dummy
plugs)
4
... Coninvers female connector for KeTop
connection cable
5
... PG glands (M16) for data lines
6
... PG glands (M16) for data lines (status
as supplied with dummy plugs)
WARNING!
Danger to persons by electric shock!
●
Only supply the device with power from voltage sources having protective
extra-low voltage (e.g. SELV or PELV acc. to IEC 61131-2)
●
Only connect voltages and circuits which are safely separated from danger-
ous voltages (e.g. by means of sufficient insulation) to connections, termi-
nals or interfaces up to a rated voltage of 50 V.
Accessories
© KEBA 2009
User's Manual V1.50
111