background image

Kemro

NX 252/A

Ethernet PCI option module

Project engineering manual V1.03

Translation of the original instructions

Summary of Contents for Kemro NX 252/A

Page 1: ...Kemro NX 252 A Ethernet PCI option module Project engineering manual V1 03 Translation of the original instructions ...

Page 2: ...10 E Mail keba keba com D KEBA GmbH Automation Leonhard Weiss Straße 40 D 73037 Göppingen Tel 49 7161 9741 0 Fax 49 7161 9741 40 E Mail keba keba com US KEBA Corp 100 West Big Beaver Road Troy MI 48084 US Tel 1 248 526 0561 Fax 1 248 526 0562 E Mail usa keba com CN Beijing Austrian KEBA Science and Technology Development Ltd Room B516 Nan Xin Cang Tower A22 Dong Si Shi Tiao Dong Cheng District Bei...

Page 3: ...reated meis 1 01 04 2009 EC directives corrected hasl 1 02 08 2010 EC directives and standards Declara tion of conformity updated hasl 1 03 08 2011 Introduction Hint not for end customers added various minor up dates fstl NX 252 A Record of Revision KEBA 2011 Project engineering manual V1 03 3 ...

Page 4: ......

Page 5: ...uidelines 15 6 Configuration 16 7 Operating behavior 17 7 1 Start up after Power On 17 7 2 Reset 17 8 Disposal 18 8 1 Disposal of the module 18 9 Technical data 19 9 1 Environmental conditions 19 9 2 Interface to the CPU module 19 9 3 Ethernet interface 19 9 4 Mechanics 19 10 EC directives and standards 20 10 1 EC directives 20 10 2 Standards 20 10 2 1 General procedures and safety principles 20 1...

Page 6: ...11 Declaration of conformity 21 Table of Contents NX 252 A KEBA 2011 Project engineering manual V1 03 6 ...

Page 7: ...ngineering degree or corresponding professional experience Knowledge in working mode of a PLC safety regulations the application Operator Basic technical training Vocational high school engineering degree or corresponding professional experience Knowledge in safety regulations working mode of machine or plant principal functions of the application system analysis and troubleshooting setting option...

Page 8: ...e of the product and should be forwarded to any subsequent owners or users of the product 1 4 1 Contents of the document Description of the Ethernet PCI option module NX 252 A Use of the Ethernet PCI option module in CPU modules Description of interface including EMC measures Technical data 1 5 Documentation for further reading The following documents are to be observed depending on the system sol...

Page 9: ...jury or slight bodily injury CAUTION CAUTION used without the safety alert symbol indicates a potentially haz ardous situation which if not avoided may result in damage to property This symbol reminds you of the possible consequences of touching elec trostatically sensitive components Information Useful practical tips and information on the use of equipment are identified by the Information symbol...

Page 10: ... the module can be destroyed or undefined signal states can lead to damage of the control system When removed from it s casing this module is sensitive to electrostatic dis charge Before handling the modules touch a grounded metal object in order to discharge any static electricity from your body Safety notes NX 252 A KEBA 2011 Project engineering manual V1 03 10 ...

Page 11: ... option module can be integrated into a 10Mbit s as well as a 100Mbit s Ethernet Information The module s functionality is only guaranteed if used within a CP 24x x or CP 25x x The module is not designed for connection with foreign modules 3 1 Front view Fig 3 1 NX 252 A front view NX 252 A Description of the module KEBA 2011 Project engineering manual V1 03 11 ...

Page 12: ... module Information The Ethernet PCI option module may not be plugged or removed if the CPU module is activated Inserting an option module into slot 1 Turn off power supply 2 Remove dummy module 3 Insert module in the correct position labelling right side into the right hand slot Installation instructions NX 252 A KEBA 2011 Project engineering manual V1 03 12 ...

Page 13: ...2 Inserting the NX 252 A Removing an option module 1 Turn off power supply 2 Pull module out of the slot 3 Insert dummy module NX 252 A Installation instructions KEBA 2011 Project engineering manual V1 03 13 ...

Page 14: ...Fig 4 3 Removing the NX 252 A Installation instructions NX 252 A KEBA 2011 Project engineering manual V1 03 14 ...

Page 15: ...Re Data Receive Data Input 4 Bi Data n c 5 Bi Data n c 6 Re Data Receive Data Input 7 Bi Data n c 8 Bi Data n c 5 1 2 Cable and plug specification Further information See system manual 5 2 EMC and wiring guidelines Pay attention from the outset to careful wiring and shielding Further information See system manual NX 252 A Connections and wiring KEBA 2011 Project engineering manual V1 03 15 ...

Page 16: ...6 Configuration No configuration is required for this module Configuration NX 252 A KEBA 2011 Project engineering manual V1 03 16 ...

Page 17: ...Power On The module is passive and is configured and activated through the HOST 7 2 Reset The module can be reset by the HOST without the HOST itself having to be reset NX 252 A Operating behavior KEBA 2011 Project engineering manual V1 03 17 ...

Page 18: ...ainer means that electrical and electronic devices including their accessories must not be disposed of in the household garbage The materials are recyclable in accordance with their labeling You can make an important contribution to protecting our environment by reusing renewing and recycling materials and old appliances Disposal NX 252 A KEBA 2011 Project engineering manual V1 03 18 ...

Page 19: ...e Connection CHAMP plug 30 pin Power supply 5 V Power consumption 5 VDC 2 W Module recognition YES Module given YES NO no type recog nized 9 3 Ethernet interface Ethernet interface 10 100 MBit s LAN Galvanic isolation Yes signaling line Number 1 Connection Modular 8 pin plug RJ45 plug 9 4 Mechanics Structure No casing only front plate mounted on print Protection class When the module is plugged in...

Page 20: ...tion This product was developed for the use in industrial areas and can cause radio interference when used in residential areas 10 2 2 EMC guideline EN 61131 2 2007 Programmable controllers Part 2 10 2 3 Electrical safety and fire protection EN 61131 2 2007 Programmable controllers Part 2 10 2 4 Environmental and surrounding conditions EN 61131 2 2007 Programmable controllers Part 2 10 3 Standards...

Page 21: ...11 Declaration of conformity NX 252 A Declaration of conformity KEBA 2011 Project engineering manual V1 03 21 ...