5.2.1
Software update via web interface
Illustration 5-8: Web interface software update
To perform a software update via the web interface, the following steps are
necessary:
1) Download the current software for the charging station (* .keb file).
2) Log into the web interface of the charging station.
3) In the main menu under "System" select the item "Software Update".
4) Upload the current software using the "Choose a file ..." button.
5) Start the update process with the "Upload & Install" button.
5.2.2
Software update via USB stick
To perform a software update on an x-series charging station via a USB
stick, the following steps are necessary:
1) Download the current software for the charging station (* .keb file).
2) Plug the USB stick into a PC.
3) Format the USB stick with FAT32.
4) Create a new directory on the USB stick with the name "
UPD
".
5) Copy the downloaded
*.keb file
into the "
UPD
" directory.
6) Connect the USB stick to the USB interface of the charging station. The
update starts automatically.
5.2.3
Software update via OCPP backend
The software update for the entire charging network can be performed via
the OCPP backend.
To perform the software update an FTP link is required. The information
downloaded from the KEBA website along with the software update contains
the FTP link.
For details on using the FTP link, see the OCPP backend manual.
Summary of Contents for KeContact P30 x-series
Page 1: ...KeContact P30 x series Konfigurationshandbuch Configuration manual ...
Page 2: ......
Page 3: ...KeContact P30 x series Ladestation Konfigurationshandbuch V 4 02 Originalbetriebsanleitung ...
Page 75: ......
Page 76: ...KEBA AG Headquarters Gewerbepark Urfahr 4041 Linz Austria www keba com 98412 ...