Local load management
45/68
4.1
Further network versions
Local DHCP server
Note
These network versions require an enabled local DHCP server in the MASTER charging station.
This feature is disabled in the delivery state.
Create a configuration file and enable the local DHCP server with the new configuration file.
Subsequently, a PC can be connected directly to the MASTER charging station via LAN. The web inter-
face can be accessed via the IP address
192.168.42.1
for the further configuration.
Parameter of the configuration file:
[NETWORK]
LocalDHCPServerEnabled=true
Connection via a switch