Commissioning
39/68
PHASES (DSW1) / ONLY FOR LOAD MANAGEMENT MODE
Phase
L1
connected to terminal 1
OFF
OFF = every 3
phases
ON
OFF = only 1
phase
Phase
L2
connected to terminal 1
OFF
ON = only 1
phase
Phase
L3
connected to terminal 1
ON
ON = only 1
phase
(*) Comments:
For load distribution, with 1-phase operating mode, any phase (L1, L2 or L3) of the power supply line can be
connected to the connection terminal 1.
The determination of which phase of the power supply line was connected serves for informing the (optional)
load management software in order to facilitate an efficient and proper load distribution.
2.2
LAN connection
Your charging station can create a connection to an OCPP host (standard connection) via a
LAN connection through your router. When using a switch instead of a router, modified configu-
rations settings are required.
1
... KeContact P30 x-series
LAN
... RJ45 or LSA+ connection
en