D3-DA 3xx/x
Connections and wiring
Project engineering manual V1.07
66
© KEBA
Pin-No.
Signal designation
Input/Output
3
Re. Data+
Receive Data +
Input
4
Bi-Data+
Bidirectional Data +
---
5
Bi-Data-
Bidirectional Data -
---
6
Re. Data-
Receive Data -
Input
7
Bi-Data+
Bidirectional Data +
---
8
Bi-Data-
Bidirectional Data -
---
Through the signals "Bi-Data+" and Bi-Data-" runs a proprietary cross com-
munication between the supply module and the axis modules of an axis
block.
6.10
Encoder connections
All encoder connections are located on the front of the device. All encoder
cables must be shielded. The cables available from KEBA are listed in chap-
ter
. Equivalent shielded cables must be used for
the connection of motors from other manufacturers.
6.10.1
Matching motor/encoder cables
Compare the rating plates of the components. Make absolutely sure to use
the correct components according to variant A, B or C!
Fig. 6-42: Motor/encoder allocation (as an example a double-axis module is shown)