Operating Instructions CDF3000
3-27
3 Installation
DE
EN
FR
IT
ES
FR
Fig. 3.12
Request "STO" on CDF3000 for shutting down in an emergency
(emergency shutdown)
ENPO
ISD00 (ISDSH)
X2
8
20
19
9
24 V +
M
3~
3
3
OSD02
(RSH)
Channel 1
Channel 2
Mains
ENPO
ISD00 (CDF,SH)
STO
Restart inhibit
Controller state
Relay
1)
OSD02 / (CDF,SH)
L
L
ON
ON
Power stage disabled via
twochannels.
high
H
3)
H
3)
OFF
OFF
Power stage ready
low
(L)
➜
H
2)
(L)
➜
H
2)
OFF
OFF
Power stage ready
low
H
(H)
➜
L
ON
ON
Power stage disabled via
twochannels.
high
(H)
➜
L
H
OFF
OFF
Power stage disabled via one
channel.
low
(L)
➜
H
H
OFF
OFF
Power stage ready.
low
( ) Previous status
1) 3 x 10
6
switching cycles at 200mA (rest position: NO contact)
2) In order to deactivate the restart inhibit the control signals must be simultaneously (ENPO max. 5 ms before ISDSH) set to High (H), or ISDSH must
be reliably set to High (H) before ENPO.
3) This only applies when STO has been disabled by the process described in "2)".
Table 3.12
Logic table for operation of the "STO"
Summary of Contents for CDF3000
Page 1: ...Positioning controller Rated current 8 A Power supply 24 48 V DC CDF3000 Operation Manual...
Page 12: ...Operating Instructions CDF3000...
Page 16: ...1 4 Operating Instructions CDF3000 1 Safety...
Page 54: ...3 34 Operating Instructions CDF3000 3 Installation...
Page 78: ...4 24 Operating Instructions CDF3000 4 Commissioning...
Page 84: ...5 6 Operating Instructions CDF3000 5 Troubleshooting...