50
brAKe cONTrOL AND TeMPerATUre DeTecTION
4.3 brake control and temperature detection
X1c
PIN
Name
Notes
1
2
3
4
5
6
1
BR+
Brake control /
2
BR-
Brake control / output -
3
Reserved
4
Reserved
5
TA1
Temperature detection / input+
6
TA2
Temperature detection / input-
Figure 20:
Assignment of the terminal block X1C
4.3.1
Specification and connection of the brake control
Name
BR+ (X1C.1); BR- (X1C.2)
function
Output to supply a brake
Output voltage
• Minimum P24V_IN - 2.4 V
• Maximum P24V_IN
Maximum output current
2 A
Others
Short-circuit proof, internal free-wheeling path;
internal filter switching
Table 25:
Specification of the brake control
2
1
I
max
=
2A
U
dc
=24V
X1C
Figure 21:
Example for the connection of the brake output at X1C