27
Power unit
4.2.3 Motor connection
4.2.3.1 AC motor connection
Terminal block X1B
Name
Description
U
V
W
PE
U
V
W
PE
PE
T1 T2
U, V, W
Motor output
PE,
Protective earth
T1, T2
Connection for temperature sensor
KTY/PTC
Functional earth
The encoder feedback connection is de-
scribed in the control circuit.
Figure 12: Motor connection AC motor
4.2.3.2 DC motor connection (option)
A shunt-, series- or compound motor can be connected. An eventually required rectifier for
the series winding is not included in the scope of delivery.
Terminal block X1B
Name
Description
U
F2
F2
V
W
A1
F1
A2
PE
T1 T2
F2, V
Output for DC motor field circuit
U, W
Output for DC motor armature circuit
T1, T2
Connection for temperature sensor
KTY/PTC
Functional earth
PE,
Protective earth
The encoder feedback connection is de-
scribed in the control circuit.
Figure 13: Motor connection DC motor