
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
X6C
X6D
X6C
X6D
Hardware
CAN | RS 485
RS 232/485
Use
Bus Communications
Diagnostics
Pin
Signal
Signal
1
CAN V+
2
CAN L
TxD, RS232
3
CAN H
RxD, RS232
4
RxD A -, RS485
RxD B +, RS485
5
RxD B +, RS485
RxD A -, RS485
6
CAN GND )
VP +5V (10mA)
7
Bus Ground
Bus Ground
8
TxD A -, RS485
TxD B +, RS485
9
TxD B +, RS485
TxD A -, RS485
The LED indicators are available only on the Serial LCD Operator. The
LEDs are used to indicate operational status. They can be used for
troubleshooting and diagnostics. In addition, the function of the LED can
be changed with parameters CH10 - 15. Refer to Section 6.12 for additional
information on CH parameters.
LED 1
LED 2
Off
No operation (noP)
Drive not enabled
(Green)
Inverter running the
motor
Run mode
Drive is able to run
(Orange)
-
Stop mode:
Drive is being
programmed or making
calculations;
F
TP file transfer mode.
(Red - Blinking)
A limit has been
reached: Torque,
Current, or Voltage (not
yet implemented)
-
(Red - Solid)
Drive is faulted
4.2 Serial/CAN
Hardware Version
4.2.1 LED Indicators
LCD Keypad
76
Summary of Contents for COMBIVERT F5
Page 1: ...COMBIVERT F5 ELEVATOR DRIVE Reference Manual Version 3 34 0F5LUB K334...
Page 203: ...203 LP Positioning Parameters LS02 LS01 LP03 LS02 LS01 LP03...
Page 347: ...Notes...
Page 348: ......