background image

  

 

Austria

 | KEB Antriebstechnik Austria GmbH  

Ritzstraße 8 4614 Marchtrenk Austria 
Tel: +43 7243 53586-0  Fax: +43 7243 53586-21 
E-Mail

[email protected]

  Internet

www.keb.at

  

 

Belgium

 | KEB America, Inc. 

Herenveld 2 9500 Geraardsbergen Belgium 
Tel: +32 544 37860 Fax: +32 544 37898 
E-Mail

[email protected]

  Internet: 

www.keb.de

  

 

Brazil

 |  KEB SOUTH AMERICA - Regional Manager  

Rua Dr. Omar Pacheco Souza Riberio, 70 
CEP 13569-430 Portal do Sol, São Carlos Brazil  
Tel: +55 16 31161294  E-Mail: 

[email protected]

  

 

France

 | Société Française KEB SASU 

Z.I. de la Croix St. Nicolas 14, rue Gustave Eiffel  
94510 La Queue en Brie France 
Tel: +33 149620101  Fax: +33 145767495 
E-Mail

[email protected]

  Internet: 

www.keb.fr

  

 

Germany

 | 

Headquarters

 

KEB Automation KG 
Südstraße 38 32683 Barntrup Germany 
T49 5263 401-0  T49 5263 401-116  
E-Mail

[email protected]

  Internet

www.keb.de

   

 

Germany

 | 

Geared Motors

 

KEB Antriebstechnik GmbH 
Wildbacher Straße 5   08289 Schneeberg Germany 
T49 3772 67-0  T49 3772 67-281  
Internet

www.keb-drive.de

  E-Mail: 

[email protected]

  

 

Italia

 | KEB Italia S.r.l. Unipersonale 

Via Newton, 2 20019 Settimo Milanese (Milano) Italia  
Tel: +39 02 3353531 Fax: +39 02 33500790 
E-Mail

[email protected]

  Internet

www.keb.it

  

Japan

 | KEB Japan Ltd. 

15 - 16, 2 - Chome, Takanawa Minato-ku 
Tokyo 108 - 0074 Japan 
Tel: +81 33 445-8515  Fax: +81 33 445-8215 
E-Mail

[email protected]

  Internet: 

www.keb.jp

  

 

P.R. China

 |  KEB Power Transmission Technology (Shanghai) 

Co. Ltd. No. 435 QianPu Road Chedun Town Songjiang District 
201611 Shanghai P.R. China 
Tel: +86 21 37746688  Fax: +86 21 37746600 
E-Mail

[email protected]

  Internet

www.keb.cn

  

 

Republic of Korea

 | KEB America, Inc. 

Room 1709, 415 Missy 2000 725 Su Seo Dong  
Gangnam Gu 135- 757 Seoul Republic Korea  
Tel: +82 2 6253 6771  Fax: +82 2 6253 6770 
E-Mail

[email protected]

  

 

Russian Federation

 | KEB RUS Ltd.  

Lesnaya str, house 30 Dzerzhinsky MO  
140091 Moscow region Russian Federation  
Tel: +7 495 6320217  Fax: +7 495 6320217 
E-Mail

[email protected]

  Internet: 

www.keb.ru

  

 

Spain

 | KEB America, Inc. 

c / Mitjer, Nave 8 - Pol. Ind. LA MASIA 
08798 Sant Cugat Sesgarrigues (Barcelona) Spain  
Tel: +34 93 8970268  Fax: +34 93 8992035 
E-Mail

[email protected]

  

 

United Kingdom

 | KEB (UK) Ltd. 

5 Morris Close Park Farm Indusrial Estate  
Wellingborough, Northants, NN8 6 XF United Kingdom  
Tel: +44 1933 402220 Fax: +44 1933 400724 
E-Mail

[email protected]

  Internet

www.keb.co.uk

  

 

United States

 | KEB America, Inc 

5100 Valley Industrial Blvd. South  
Shakopee, MN 55379 United States  
Tel: +1 952 2241400  Fax: +1 952 2241499 
E-Mail

[email protected]

  Internet

www.kebamerica.com

  

 

 

Summary of Contents for COMBIVERT F5

Page 1: ...COMBIVERT F5 INSTRUCTION MANUAL BRAKE TRANSISTOR MONITOR Original manual Brake Transistor Monitor Document 20231183 USA 00 Material No 00F5LUZ K004...

Page 2: ...2 2020 KEB America Inc...

Page 3: ...ing signs DANGER Dangerous situation which will cause death or serious injury if this safety warning is ignored WARNING Hazardous situation which may cause death or serious injury if this safety warni...

Page 4: ...our control and therefore exclusively the responsibility of the machine manufacturer system integrator or customer The information contained in this document as well as any user specific advice in sp...

Page 5: ...ansistor Monitor 10 2 Safety Instructions 11 2 1 Target Audience 11 2 2 Specified Application 11 2 3 Electrical Safety Guidelines 12 3 Product Description 13 3 1 Scope of this Manual 13 3 2 Overview 1...

Page 6: ...8 5 2 Electrical Installation 19 5 2 1 Terminals 19 5 2 2 Wiring Diagrams 20 5 2 2 1 DC Brake Resistor Contactor 20 5 2 2 2 AC Line Contactor 21 6 Appendix 22 6 1 Appendix 1 Recommended Distribution B...

Page 7: ...f Figures 2020 KEB America Inc 7 List of Figures Figure 1 Dimensions 17 Figure 2 Mounting Dimensions 18 Figure 3 Terminals 19 Figure 4 Wiring Diagram DC Contactor 20 Figure 5 Wiring Diagram AC Contact...

Page 8: ...Inc List of Tables Table 1 Climatic environment conditions 14 Table 2 Mechanical ambient conditions 14 Table 3 Device classification 15 Table 4 Electromagnetic compatibility 15 Table 5 Rated values 1...

Page 9: ...l Brake Transistor Transistor which commutates the excess energy in the DC bus of the drive into the braking resistor Machine Manufacturer The manufacturer of the application to which the KEB product...

Page 10: ...rds for electric installations in Canada NFPA 70 National Electric Code NEC o Region US o Electric safety code detailing safety standards for electric installations in the United States NFPA 79 Electr...

Page 11: ...contained in this manual Must be familiar with the installation and assembly of electrical products Must be familiar with the installation and operation of the product as specified in this manual See...

Page 12: ...specific to the product Use only wire gauges rated for the power requirements of the device Ensure new or existing circuits meet NEC or applicable local requirements For low voltage conductors that a...

Page 13: ...t can cause the resistor to overheat and potentially catch fire resulting in damage to the equipment or dangerous safety hazards The KEB Brake Transistor Monitor is specifically designed to check whet...

Page 14: ...conductive pollution occasional condensation when the unit is out of service Site altitude Max 2000 m above sea level Table 1 Climatic environment conditions 4 1 2 Mechanical Ambient Conditions Storag...

Page 15: ...s Description Conducted emissions EN 61800 3 C2 Radiated emissions EN 61800 3 C2 Immunity Standard Level Description Static discharges EN 61000 4 2 8kV 4kV AD air discharge CD contact discharge Burst...

Page 16: ...120VAC Monitor Input BR BR 350 to 800VDC 840VDC maximum On time to trigger contact state change 64ms Table 5 Rated values i If the control voltage applied to contacts K1 and K2 is 120VAC the safe ins...

Page 17: ...Installation 2020 KEB America Inc 17 5 Installation 5 1 Mounting 5 1 1 Dimensions Figure 1 Dimensions...

Page 18: ...ontrol cabinet ensuring the monitor is mounted an appropriate distance from any other control elements as shown in the following table Mounting Distance Dimension Distance mm Distance inch A 150 6 B 5...

Page 19: ...0 Nm 18 in lbs BR Earth Ground Connection Terminal Function Connection Tightening Torque GND Connection to Ground M5 screw Use UL listed ring style crimp connector Recommended wire gague 4 0mm2 or 12...

Page 20: ...n Connection Block BR Brake Resistor DC DC Contactor VC Control Voltage Com Control Voltage Common i The terminals on the Drive and the Brake Transistor Monitor are rated for single conductor only Two...

Page 21: ...tor LC Line Contactor RC Reset Relay Latching Circuit VC Control Voltage Com Control Voltage Common i The terminals on the Drive and the Brake Transistor Monitor are rated for single conductor only Tw...

Page 22: ...required nVent ERIFLEX UD 80A 569010 https www erico com part asp part UD 80A KEB Material Number 0090503 5001 6 2 Appendix 2 Recommended DC Contactor Used to disconnect the BR connection to the brak...

Page 23: ......

Page 24: ...33500790 E Mail info keb it Internet www keb it Japan KEB Japan Ltd 15 16 2 Chome Takanawa Minato ku Tokyo 108 0074 Japan Tel 81 33 445 8515 Fax 81 33 445 8215 E Mail info keb jp Internet www keb jp...

Page 25: ...Automation with Drive www kebamerica com KEB America Inc 5100 Valley Industrial Blvd S Shakopee MN 55379 Tel 1 952 224 1400 E Mail info kebamerica com...

Reviews: