Size
Housing
P
N
I
N
C
int
Load-shunt
Max.
charging
current
R
Type
400V
kW
A
uF
Ω
–
A
21
R
45
90
4950
5.0
–
–
22
R
55
115
4950
5.0
–
–
23
R
75
150
6350
5.0
–
–
24
R
90
180
8400
5.0
–
–
23
U
75
150
6350
5.0
–
–
24
U
90
180
8400
5.0
–
–
25
U
110
210
9900
2.5
–
–
26
U
132
250
11700
2.5
–
–
27
U
160
300
14100
2.5
–
–
28
P
200
370
16200
5.8
–
–
29
P
250
460
19800
5.8
–
–
30
P
315
570
19800
5.8
–
–
32
P (M+S)
400
710
39600
2.9
–
–
33
P (M+S)
450
800
39600
2.9
–
–
34
P (M+S)
500
890
39600
2.9
–
–
35
P (M+S)
560
1000
39600
2.9
–
–
36
P (M+S+S)
630
1150
59400
1.9
–
–
Legend
P
N
Rated power
I
N
Rated current
C
int
Real capacity
Table 19: Technical data of COMBIVERT drive converters
NOTICE
A restart for AIC with NTC is allowed only after 5 minutes.
60
DIMENSIONING
Summary of Contents for COMBIVERT F5 Series
Page 2: ......