Page 6.2 - 18
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Start-up
11.
Adjustment of specific data
⇒
dS.02 current decoupling = 1 : on
⇒
uF.15 hardw. curr. lim. mode = 0: off
Overload characteristic of the motor:
⇒
dr.33 DSM max. torque (otherwise 5* dr27 rated tor-
que)
12. Optimize speed controller
See chapter 7.11 for all data of the adjustment
The start-up is successful completed if no error messages have arisen.
A detailed parameter description and their effects are described in chapter 7.6.
6.2.2.2 Start-up F5E-S (SCL)
The following steps describe a standard start-up when using a KEB motor or "customer-specific motor“. An
encoder feedback is not used.
1.
Open control release
deactivate terminal X2A.16
⇒
ru.00 inverter state = nop/ „no control release“
2.
Selection of the speed range
The usable speed range is adjusted with Ud.02:
⇒
Ud.02 control type = 8…11
See chapter 5.1 for all data of the adjustment
3.
Loading the default parameters
⇒
Fr.01 copy parameter set = - 4
4.
Select source of the speed feedback
⇒
cS.01 actual source = 2 : calculated actual value
5.
Input of the motor rating plate data
⇒
dr.23 DSM rated current
⇒
dr.24 DSM rated speed
⇒
dr.25 DSM rated frequency
⇒
dr.26 dr.26 DSM EMC [Vpk*1000RPM]
[Vpk x 1000rpm] *
⇒
dr.27 DSM rated torque
⇒
dr.28 DSM curr. f. zero speed
⇒
dr.30 DSM winding resistance *
⇒
dr.31 DSM winding inductance *
* Note:
dr.30 and dr.31 must be entered as phase-
phase value (R
UV
, L
UV
).
Equivalent circuit data must be entered
according to the data sheet OR the data
must be identified automatically like step 7.
dr.26 must be programmed as peak value of
the phase-phase voltage U
UV
.
6.
Calculation of motor-dependent data
⇒
Fr.10 load motor-dep. parameter = 2: act. DC link
voltage
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...