Start-up
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 6.2 - 17
6
6.
Input of the motor rating plate data
⇒
dr.23 DSM rated current
⇒
dr.24 DSM rated speed
⇒
dr.25 DSM rated frequency
⇒
dr.27 DSM rated torque
⇒
dr.28 DSM curr. f. zero speed
Note: If dr.28 is not indicated, the appro-
ximation value of dr.23 (rated current) can
be used.
Stator resistance and inductance must be
preset as phase-phase values (R
UV
. L
UV
)
and the EMC must be preset as peak value
of the phase-phase voltage (√2 x U
UV
).
The values can be taken from a data sheet
OR they can be automatically identified.
Identification: see step 10.
7.
Input of equivalent circuit data
- dr.30 DSM winding resistance
- dr.31 DSM winding inductanc
- dr.26 DSM EMC [Vpk*1000RPM]
8.
Calculation of motor-dependent data
⇒
Fr.10 load motor-dep. parameter = 2: act. DC link
voltage
9.
Adjust system position
-Checking the direction of rotation. ru.09 must display a
positive speed at manual forward direction of rotation.
-Motor shaft must be mandatory free-wheeling (no-load
operation).
⇒
Ec.02 system position 1 = 2206
-close control release (X2A.16)
⇒
After successful measurement ru00 = 127 : cddr/ „drive
data calculated“ is displayed.
-open control release again (X2A.16)
See chapter 7.6. for all data of the system
position trimming.
10.
if necessary identification of the equivalent circuit data
⇒
dr.48 motor identification = 7: Auto identification wit
-
hout EMC
-close control release (X2A.16)
⇒
After successful identification ru00 = 127 : cddr/ „drive
data calculated“ is displayed.
-open control release again (X2A.16)
Note:
The EMC is not measured by identification,
but it is calculated from the rated data.
Read chapter 7.6 for further data of the
identification
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...