Page 7.15 - 26
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Special functions
Addr.
Value
Notice
rG.01
0.5%
Gear factor is known ( i_slave/i_master => ec.58 =230, ec.59=98 ) and adjustable
without error
rG.02
4600 Inc
One period is e.g. 230000 inc at the slave and a deviation per revolution can only be
a few increments. Thus 2° per period is compensated
rG.03
1 ms
If the gear factor is compensated the deviation amounts approx. 0.5 ms
rG.04
16
Input I1 slave
rG.05
32
Input I2 master
rG.06
1
Only one pulse per revolution of the master
rG.07
1
Only one pulse per revolution of the slave
rG.08
30000 inc
Angle deviation from the master to the slave drive, compensate only upto 50 rpm
(positive direction of rotation)
rG.09
50 rpm
rG.10
0 inc
No second interpolation point, constant rG.08
rG.11
4000 rpm
No angle deviation > rG.11
7.15.10
Technology control
The KEB COMBIVERT is equipped with an universal programmable technology controller, which is able to
create pressure control, temperature or dancer position control.
7.15.10.1 The PID controller
The technology controller consists of a setpoint/actual value comparator, which transmits the system deviation
to the PID controller. The P- I- and D-component is adjusted with cn.04, 05 and 06. Parameters cn.07 and cn.08
limit the max. manipulated variable of the controller.
The controller ratio is defined from 0… 100% with the PID fading time (cn.09).
Parameter cn.14 adjusts the fre-
quency ratio in Hz/% (only F5-G/B). The PID controller, the I-component separately and/or the controller fading
can be reset with parameters cn.11, 12 and 13. A PID reset condition can be adjusted with cn.10.
PID controller
ru.52
cn. 07
cn. 08
cn.14
cn.04 PID kp
cn.05 PID ki
cn.06 PID kd
cn.09 PID
Fading time
cn.10 PID reset
Condition
cn.11 PID reset
input selection
cn.12 I reset
input selection
cn.13 reset
Fading /
input selection
%
Hz
+
-
see
oP.00
see
cs.00
Digital inputs
Setpoint calculation
Actual value
calculation
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...