Special functions
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.15 - 19
7
Parameter oP.44 determines which source presets the amplitude height of the sweep function.
oP.44: Ext. function mode /source
Bit
Meaning
Value
4...7
Adjust input
source
0: AN 1 input (ru.28)
16: AN 2 input (ru.30)
32: AN 3 input (ru.32)
48:digital source (oP.45)
64: AUX input (ru.53)
The sweep amplitude can be preset also via oP.45 „ext. function digital source“ in the range of 0… 100%, be-
side to the analog setting via AN 1, AN 2, AN 3 or AUX.
Change of the sweep amplitude
The maximum rate of change of the sweep amplitude is limited with parameter oP.46 „ext. function acc/dec.
time“.
Parameter oP.46 defines a time between 0.00...20.00 s, inside the sweep amplitude can increase or decrease.
The specified value refers to a sweep amplitude change of 100 %.
Period of the sweep period
The acceleration time is parameterized with oP.47 „sweep-gen. acceleration time“, the deceleration time of the
sweep signal with oP.48 „sweep-gen. deceleration time“.
Both times are adjustable within the range of 0… 20.00 s.
Together the two parameters result in the period duration of the wobbel period.
Operating principle of the wobble function
The following picture shows the setpoint process, which is generated by the wobble function:
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...