Selection of Operating Mode
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 5.1 - 3
5
5. Selection of Operating Mode
This instruction manual is valid for the following software conditions:
S o f t w a r e
type
Control type
(Adjustment ud.02)
Description
F5A V4.30
4: F5-M / 4000rpm
Standard software
for the operation:
- of asynchronous motors with vector control
- of asynchronous motors with V/f characteristic control
- of synchronous motors with
vector control
5: F5-M / 8000rpm
6: F5-M / 16000rpm
7: F5-M / 500rpm
8: F5-S / 4000rpm
9: F5-S / 8000rpm
10: F5-S / 16000rpm
11: F5-S / 500rpm
F5A V4.31
4: F5-M / 4000rpm
Software for motors with maximum speed upto 128000 rpm (high frequency ap-
plications)
corresponds to standard software F5A-M V4.30, except for:
• control type 7 or 11 is for a maximum speed of 32000 rpm instead of 500 rpm
• additional control types 12 / 13 or 14 / 15 for motors with a maximum speed of
64000 rpm or 128000 rpm
(Attention: With output frequencies > 800Hz or if the ratio output frequency to rated
clock frequency is less than 1:10, contact KEB for application design).
5: F5-M / 8000rpm
6: F5-M / 16000rpm
7: F5-M / 32000rpm
12: F5-M / 64000rpm
13: F5-M / 128000rpm
8: F5-S / 4000rpm
9: F5-S / 8000rpm
10: F5-S / 16000rpm
11: F5-S / 32000rpm
14: F5-S / 64000rpm
15: F5-S / 128000rpm
F5H V2.30
4: F5-M / 4000rpm
Software for the speed-controlled operation of asynchronous motors without
speed feedback
- The measured speed is replaced by an estimated speed actual value, which is formed
by means of a mathematical model of the asynchronous motor.
- Operation with speed feedback also possible.
5: F5-M / 8000rpm
6: F5-M / 16000rpm
7: F5-M / 500rpm
F5H V2.31
4: F5-M / 4000rpm
Software for the speed-controlled operation of asynchronous motors without
speed feedback with a maximum speed upto 128000rpm
- control type 7 or is for a maximum speed of 32000rpm instead of 500rpm
- additional control types 12 and 13
(Attention: limitations see high frequency software F5A V4.31)
5: F5-M / 8000rpm
6: F5-M / 16000rpm
7: F5-M / 32000rpm
12: F5-M / 64000rpm
13: F5-M / 128000rpm
F5E V2.30
8: F5-S / 4000rpm
Software for the speed-controlled operation of synchronous motors without
speed feedback
- The measured speed is replaced by an estimated speed actual value, which is formed
by means of a mathematical model of the synchronous motor
- Operation with speed feedback also possible
9: F5-S / 8000rpm
10: F5-S / 16000rpm
11: F5-S / 500rpm
F5E V2.31
8: F5-S / 4000rpm
Software for the speed-controlled operation of synchronous motors without
speed feedback with a maximum speed upto 128000rpm
- control type 11 or is for a maximum speed of 32000rpm instead of 500rpm
- additional control types 14 and 15
(Attention: limitations see high frequency software F5A V4.31)
9: F5-S / 8000rpm
10: F5-S / 16000rpm
11: F5-S / 32000rpm
14: F5-S / 64000rpm
15: F5-S / 128000rpm
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...