Parameter sets
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.14 - 5
7
7.14.6
Copying of parameter sets via bus (Fr.01, Fr.09)
Two parameters are responsible at indirect set-addressing for copying of parameter sets via bus.
Fr.09 defines
the target set. Fr.01
defines the source parameter set and starts the copying process.
The source set (Fr. 01)
is copied in the selected parameter sets at direct set-programming. The following copying actions can be prac-
tised:
Target
set
Fr.09
Source set
Fr.01
Action
0...7
0...7
All programmable parameters (System parameters too) of the source set
are copied into the target set.
0
-1: dEF_S
Default values are copied into all parameters of set 0 (with exception of
System and Security parameters).
1...7
-1: dEF_S
Default values are copied into all programmable parameters of the target
set (with the exception of System and Security parameters).
All
-2: dEF_A
Default values are copied into all parameters of all sets (with the exception
of System and Security parameters).
0
-3: ini_S
Default values are copied into all parameters of set 0 (with the exception of
Security parameters).
1...7
-3: ini_S
Default values are copied into all programmable parameters of the target
set (with the exception of Security parameters).
All
-4: ini_A
Default values are copied into all parameters of all sets (with the exception
of Security parameters).
By loading the factory setting all definitions defined by the mechanical engineer are reset
! This can comprise
the terminal assignment, set changeover or operating states. Before loading the default set it is to be ensured
that no unintended operating states occur.
Custom-specific default values
Value
Fr.01
Source Default values
copied parameters
Target sets
-1
KEB
Customer parameters
selected
-2
KEB
Customer parameters
all
-3
KEB
Customer and system parameters
selected
-4
KEB
Customer and system parameters
all
-5
custom-specific
Customer parameters
selected
-6
custom-specific
Customer parameters
all
-7
custom-specific
Customer and system parameters
selected
-8
custom-specific
Customer and system parameters
all
-9
Storing of the current parame-
ter setting as custom-specific
default values.
Customer and system parameters
all
The values -5 to -8 are corresponding to the previous values -1 to -4 referring to the copied parameters and
target sets. They differ only in the default value source.
Value -9 enables storing of the current parameter setting as custom-specific default values. The values of all
customer and system parameters are stored in all sets thereby.
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...