PS.35: Teach mode
Value
Explanation
0: Write index PS.23
The actual position is written in the positioning block selected by para-
meter PS.23 „index/selection“.
1: Write index PS.23 incr.+1
The current position is written in the positioning block selected by para-
meter PS.23 "index/selection" and then PS.23 is increased by 1 (limited
to maximum index 31).
2: Write index PS.28
The current position is written in the positioning block selected by para-
meter PS.28 "start index new profil". Since PS.28 is set-programmable,
positions can be linked with sets this way.
3: Write index PS.58
The current position of PS.59 is written in the index of PS.58.
4: Write index PS.58 incr.+1
The current position of PS.59 is written into the index of PS.58. Then the
position index is increased by 1.
5: Write index PS.56
The selection of the index is determined by the source of PS.56.
Example: Teaching of target position
An undercarriage shall "learn" the position values belonging to a storage location (the position values shall
be teached). In inching mode, the drive is brought to the position that is to be used later as the target of the
positioning (i.e., the storage location in a shelf). The drive is in speed-controlled mode, i.e., the input activating
the posi mode is not set.
Since several storage locations are to be taught consecutively, the setting is PS.35 "teaching mode" = 1. If the
correct position is reached, it is registered as the target position by the teach-pulse. After that, the next storage
location is approached.
The following figure illustrates the example:
PS.24 Index 1
PS.24 Index 2
PS.24 Index 0
ru.54: actual position
PS.24: index / position
ru.02: ramp
output display
T
each pulse
PS.23: index /
selection
With the digital inputs, 3 constants are selected:
●
higher speed for coarse target approach constant
1 = 300 U/min
●
inching mode for exact target approach
Fixed value 2 = 50 rpm
Fixed value 3 = -50 rpm
The desired position is approached in vector controlled
operation.
With a teach-pulse (positive edge of the chosen digital
input), the current actual position is registered as the
target position of a positioning block.
The process starts with the index currently selected in
PS.23. Thereafter, the index is increased after every
target position acquisition.
Posi- and synchronous operating
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.12 - 73
7
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...