All other bits can remain at the factory settings for this example and are explained in the following chapters.
●
Block 0 defines the start position
→
PS.28 = 0
●
block 0
→
PS.23: Index / selection = 0
Position = 0
→
PS.24: Index / position = 0
Permitted max. speed = 1500 rpm
→
PS.25 = 1500 rpm
next positioning step defined in block 1
→
PS.26 = 1
no automatic starting of the drilling process, but waiting for "start position" command, i.e. "continuati-
on of the profile processing“ = 0: no and „position setting“ = 0: absolute
→
PS.27 = 0: no + absolute
●
block 1
→
PS.23: Index / selection = 1
Position = material surface
→
PS.24: Index / position = 95000
Advance to material surface
→
PS.25 = 1500 rpm
next positioning step defined in block 2
→
PS.26 = 2
automatic continuation of the drilling process, i.e., "continuation of the profile processing" = 1:yes and
"Position setting" = 0:absolute
→
PS.27 = 1: yes + absolute
●
block 2
→
PS.23: Index / selection = 2
Position = end of penetration
→
PS.24: Index / position = 100.000
max. speed penetration
→
PS.25 = 250 rpm
next positioning step defined in block 3
→
PS.26 = 3
automatic continuation of the drilling process
→
PS.27 = 1: yes + absolute
●
block 3
→
PS.23: Index / selection = 3
Position = end of drilling
→
PS.24: Index / position = 150.000
max. speed drilling
→
PS.25 = 500 rpm
next positioning step defined in block 4
→
PS.26 = 4
automatic continuation of the drilling process
→
PS.27 = 1: yes + absolute
●
block 4
→
PS.23: Index / selection = 4
Position = material surface
→
PS.24: Index / position = 95.000
max. speed retraction
→
PS.25 = 700 rpm
Retraction to starting position defined in block 0 →
PS.26 = 0
automatic retraction to starting position →
PS.27 = 1: yes + absolute
Posi- and synchronous operating
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.12 - 43
7
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...