Speed measurement
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.11 - 25
7
For this the supervisor password must be entered and Ec.38 = „2: memory activated“ must be written.
If an error occurs during storage, Ec.37 displays the status „68: no communication to the encoder“. In case of
successful storage, bit „storage activated“ is automatically reset.
The system and application data are always stored!
7.11.11.6 Encoder over gear (ec.39)
This parameter allows the operation of encoders that either are not mounted directly to the motor (output, belt),
whose detection have a superior position evaluation (e.g., pole-pair resolver) or whose increments per revolu-
tion cannot be set in ec.01.
Ec.39: encoder over transmission
Value Function
Description
0
off
No function
1
Motor – Encoder
Speed ratio in the encoder detection. Position values are evaluated
1:1, gear factor ec.04/05 enters the speed measurement.
2
Ec.01 x Ec.05 (1 zero
pulse /revolution)
The increments per revolution of the encoder is greater than the para-
meter in ec.01 allows. The zero signal is once per revolution
3
Ec.01 x Ec.05 (spacer-
coded)
like 2, but the zero signal is spacer-coded (500inc / 500 inc = zero
position)
4
reserved
Special software (like 2, but the zero signal is validated via an external
reference switch).
5
Motor – E syn-
chronous channel 2
For channel 1 as 1. The motor is operated under control of an encoder
coupled to the output. Via channel 2, control occurs position-synchro-
nous. The gear factor in channel 1 is cosidered in the speed detection
of channel 2.
7.11.11.7 Consider deceleration times of the position sensing
Addr.
Parameter
Name
Default value
Value
1126h
dS.38
encoder delay
0: Off
0 = off
1 = on
As standard the delay time for resolver and incremental encoder detection is set to "0 off" in order not to affect
existing applications. Parameter dS.38 must be set to "1 on" to activate the encoder delay.
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...