Speed measurement
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.11 - 13
7
Encoder trigger (Ec.07, Ec.17)
Value
Evaluation of the encoder signals
0
1-fold (for initiator: evaluation of positive edges only) (2
0
)
1
2-fold (for initiator: evaluation of positive and negative edge)(2
1
)
2
4-fold (for incremental encoder) (2
2
) default
3
8-fold (23)
4
16-fold (24)
5
32-fold (25)
6
64-fold (26)
...
...
13
8192-fold (213)
Position value for channel 2 via parameter (Ec.28)
An encoder is connected to the master control. The position value is written to parameter Ec.28 via bus.
Rotary encoder:
The control detects the whole revolutions and outputs a continuous position value to
Ec.28
Linear encoder:
The controller detects the position value and outputs it toEc.28
Adjustment:
Ec.10 = 30 = „Position via Ec.28“. Independent of connection to channel 2.
Increments per revolution Ec.11 (128….16384, default 1024 inc)
Multiturn resolution Ec.21 ( 32….32, default 32 )
Resolution Ec.17 ( 2….9, default 9)
Position format:
The position value in a range of -2^31….2^31.1 is described in Ec.28.
The display standardization can not be changed with
Ec.41. The overflow detection after power-on is not
supported!
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...