Motor adaption
Fr.10 = 2 (for some applications Fr.10 = 1 /explanation see below) must be entered once after input of the motor
data.
The parameter can only be written in „nop“ status !
Fr.10 load motor dependent parameter
Value
Function
0: finished
1: uF.09
Calculation depending on uF.09 respectively voltage class
2: actual DC link
voltage
Calculation depending on act. DC link voltage
The calculation at Fr.10 = 1 is depending on the voltage entered in parameter uF.09 "Voltage stabilisation". If
this parameter displays "off" (standard adjustment), then the voltage class of the frequency inverter (400V or
230V) is used.
The current DC link voltage of the frequency inverter, which is proportional to the supply input voltage, is con-
sidered for the calculations at Fr.10 = 2.
However this only applies uF.09 is on "off".
Thus the following parameter are pre-charged dependent on the motor and inverter data:
Current controller
- dS.00
Kp current
- dS.01
Ki current
Torque limits:
- cS.19
Absolute torque reference
- cS.20...23
Torque limits clockwise- counter clockwise rotation/ motoring- generating
- Pn.61
Abnormal stopping torque limit
- dr.33
DSM max. torque
Motor type (only at SCL):
- nn.01
Stabilisation current
- nn.02
lower speed limit / stabilisation
- nn.03
upper speed limit / stabilisation
- nn.10
Standstill current
- nn.11
Type stabilization time constant
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...