Setpoint, rotation- and ramp setting
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.4 - 9
7
In run/stop and forward/reverse rotation setting (oP.01= "4" or "5") the inputs determined with oP.60 and oP.61
work as follows:
forward
reverse
Input
X2A.14
X2A.15
F
R
Function
0
0
LS
0
1
LS
1
0
forward
1
1
reverse
Rotation direction is dependent on the sign of the set value
The direction of rotation can be defined with the preadjusted set value signal. In the case of analog signals
through adjustment of positive or negative voltages. In the case of digital signals through adjustment of positive
values (without sign) or negative values (negative sign in the display).
Following adjustments are possible:
Evaluation with LS (Switch off the modulation) (oP.01 = 6, 10 or 11)
In this case „F“ or „R“ must be set via a digital input, digital via oP.02 or "start" via control word SY.50 in order for
the inverter to modulate. It is unimportant which rotation setting is used, as the direction of rotation is dependent
on the setpoint.
oP.01 = 10:
The rotation direction release is done exclusively via the control word Run/Stop.
oP01 = 11:
Function is like at value 10 only without deceleration ramps. The modulation of the frequen-
cy inverter is disabled and the motor will coast down if the direction of rotation is disabled.
No direction of rotation is set
->
LS (Modulation disabled)
A direction of rotation is set and oP.01 = 6, 10 or 11
->
forward direction with positive setpoint
->
reverse direction with negative setpoint
Evaluation without LS (oP.01 = 7)
In this case the inverter modulates always. No direction of rotation needs to be adjusted.
oP.01 = 7:
positive setpoints (also 0)
->
forward direction of rotation
negative setpoints
->
reverse direction of rotation
Direction of rotation depending on the inverter control word Sy.50 (oP.01 = 8 or 9)
The control word is used for the state control of the inverter via bus. In order for the inverter to react to the con-
trol word, the respective control process must be enabled (oP.01=8 or 9). When setting the direction of rotation
via the control word, the setpoint can be evaluated 0-limited (oP.01 = 8) or absolute (oP.01 = 9).
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...