Page 7.3 - 28
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Digital in- and outputs
The next table indicates an overview of the functions, which can be assigned additionally to a digital input with
parameters di.24.. di.35 (only one auxilliary function is possible per input / bit 31 „I+ function“ must be activated
for the appropriate input):
di.24...di.35: Input- „+“ function
Value
Explanation
Fct. Para
1)
0: Reset master slave difference
Master position (ru.56) is overwritten with the slave po-
sition (ru.54)
PS.11
1: Set reference point
Actual position (ru.54) is overwritten with the reference
position (PS.17)
PS.13 *
2: Store position (teach)
actual position (ru.54) is transferred as target position
in PS.24
PS.36 *
3: Scan position
during state "active positioning" the actual position is
stored with positive edge at the input in ru.71 „Teach/
scan position display“.
PS.37 *
4: Relative position F/R
Rotation setting for relative positioning (only if in PS.27
for position setting the mode „relative to PS.38“ is se-
lected
PS.38
5: Software ST (not at di.35)
any digital input gets the function "control release" (soft-
ware emulation / function can not be set to input ST)
di.36
6: ST locking (not at di.35)
Setting the input effects a locking of the software con-
trol release
di.37
7: Reference point correction
Connection of the switches for flying referencing at slip-
afflicted systems
PS.43
8: Brake monitoring
Between the end of the brake closing period (Pn.40)
and the beginning of the break opening period (Pn.36)
the brake must always be closed. If the input becomes
(or is) active during this phase, E.br is triggered.
Pn.42
9: Dead time compensation off
As long as the input is active, the dead time compensa-
tion is switched off
uF.21
10: USV operation 400V class
Activation of the input causes reduction of the level for
triggering and resetting of the undervoltage error
Pn.78
11: no digital ST (di.35 no function)
Control release only preset via terminal block (di.01 /
di.02 and control word SY.43 / SY.50 without function)
di.39
12: Start autom. Rs temperature
correction
Start of the temperature-dependent stator resistance
adaptation (only at V/f characteristic open-loop opera-
tion and SMM)
dr.61
13: Encoder channel 2 / transfer
value
The value of Ec.61 - Ec.32 before (at 14: and Ec.60
- Ec.31 before) is scanned with the positive edge and
stored in Ec.50 / Ec.51
EC.48
14: Encoder channel 1 + 2 / trans-
fer value
EC.49
15: reserved
16: Register fct. Master input
17: Register fct. Slave input
18: Target position
Determines the input for selection of positions. Evalua-
tion depending on PS.56.
PS.57
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...