KEB COMBIVERT F4-C
4
Name: Basis
09.02.98
Operation
Drive-Mode
©
KEB Antriebstechnik, 1997
All Rights reserved
Chapter
Section
Page
Date
4.4.4 Rotation Setting
Setting possibilities:
F = forward (clockwise rotation)
r = reverse (counter-clockwise rotation)
Each actuatin of the key
ENTER causes a change in
rotational direction
START
STOP
FUNC.
SPEED
ENTER
F/R
START
STOP
FUNC.
SPEED
ENTER
F/R
ENTER
F/R
4.4.5 Start / Stop / Run
Status „Run“
The drive runs with
preselected frequency
(e.g. „F 50.0“)
Status „Stop“
Power module
disconnected, drive
is freewheeling
(e.g. „F LS“)
START
STOP
FUNC.
SPEED
ENTER
F/R
START
STOP
FUNC.
SPEED
ENTER
F/R
START
STOP
3 operating states exist in the Drive-Mode:
Status „Start“
Power module is controlled
with 0 Hz, drive stands
with holding torque
(e.g. „F 0.0“)
Among other things the parameter ud.9 determines in what way the keys START and
STOP approach the individual operating states:
Stop
Run
ud. 9 = 0 or 1
(standard)
START
STOP
FUNC.
SPEED
ENTER
F/R
START
STOP
FUNC.
SPEED
ENTER
F/R
START
STOP
Start
Run
ud. 9 = 2 or 3