![KEB COMBIVERT F4-C Applications Manual Download Page 263](http://html1.mh-extra.com/html/keb/combivert-f4-c/combivert-f4-c_applications-manual_3852415263.webp)
11
2
6
Networks
Bus-/DRIVECOM-Parameter
Chapter
Section
Name:Basis
©
KEB Antriebstechnik, 1996
All Rights reserved
Page
Date
26.03.98
KEB COMBIVERT F4-C
Adr.
min
max
default
Adr.
min
max
default
Adr.
min
max
default
Adr.
min
max
default
Adr.
min
max
default
Pr. 18 Acceleration Delta time
0112h
0
32767
1
10
sec
Adjustment of the time that serves for the calculation of acceleration ramp.
Pr. 25 Deceleration Delta speed
0119h
1
32767
1
1500
1/min
Adjustment of speed change that serves together with Pr.27 for the calculation of the deceleration ramp.
Pr. 27 Deceleration Delta time
011Bh
0
32767
1
10
sec
Adjustment of the time that serves for the calculation of the deceleration ramp.
Pr. 37 Speed reference variable
0125h
-32767
32767
1
-
1/min
Speed at the output of the ramp generator.
Pr. 38 Percent setpoint value
0126h
-200
200
0,61
0
%
Setpoint setting in percent referred to Pr.39. 16383
∧
100% = Pr.39
The setpoint value is calculated according to following formula:
Reference value (Pr.39) · Percentual value(Pr.38)
Setpoint =
100%