KEB COMBIVERT F4-C
Name: Basis
29.01.98
6
Functional Description
Parameter Sets
©
KEB Antriebstechnik, 1997
All Rights reserved
Chapter
Section
Page
Date
Param.
Adr.
min
max
default
ENTER
PROG.
R/W
Step
1
2
3
4
5
6
6.8.6
Used Parameters
Fr.0
2700h
✔
✔
✔
-2
7
1
0
not via bus
Fr.1
2701h
✔
-
-
-2
7
1
0
not via keyboard
Fr.2
2702h
✔
-
✔
0
3
1
0
-
Fr.3
2703h
✔
-
✔
0
255
1
0
-
Fr.4
2704h
✔
-
✔
0
7
1
0
-
Fr.5
2705h
✔
✔
-
0
2,55 s
0,01 s
0
-
Fr.6
2706h
✔
✔
-
0
2,55 s
0,01 s
0
-
Fr.9
2709h
✔
-
-
-1
7
1
0
not via keyboard
6.8.5
Parameter Set ON
and OFF Delay
(Fr.5, Fr.6)
With these parameters the time is adjusted
- by which the activation of a new set shall be delayed (Fr.5)
- by which the deactivation of a set shall be delayed (Fr.6)
At set changeover the turn-off time of the old set and the turn-on time of the new set
are added up.
Set 1
Set 3
Set 2
Set 1
Set 3
Set 2
Set 0
Set 0
Preselected set
Actual set
Picture 6.8.5
ON and OFF delay
Example
Set
Fr.5
Fr.6
0
0 s
0 s
1
2 s
0 s
2
0 s
1 s
3
2 s
2 s
1:
ON delay set 3 of 2s
2:
OFF delay set 3 of 2s
3:
OFF delay of set 2 of 1s +
ON delay of set 1 of 2 s
4:
immediate changeover as no delay-time is adjusted
5:
OFF delay set 2 of 1s +
ON delay of set 3 of 2s
6:
OFF delay of set 3 of 2s