6.8
Parameter Sets
6.8.2
Copying of Para-
meter Sets
(Fr.0, Fr.1, Fr.9)
The KEB COMBIVERT has 8 parameter sets (0…7), i.e. all programmable parameters
exist 8-times in the inverter and can be assigned with different values independent of
each other. Thus it is possible for example to operate 8 different motors on one inverter,
that means that the motor dates of each motor are in a separate set. Since many of
the parameters in the parameter sets have the same values, it would be quite
troublesome to adjust each parameter in each set individually. The following section
describes how complete parameter sets are copied, locked, selected and how the
inverter is initialized again.
6.8.1
Non-
programmable
Parameters
Certain parameters are non-programmable, since their value must be the same in all
sets (e.g. bus address or baud rate). To identify these parameters at once the parameter
set number is missing in the parameter identification.
The same value always applies
to all non-programmable parameters independent of the selected parameter
set!
Fr.0
⇓
copying of
parameter sets via
keyboard
Fr.1 and Fr.9
⇓
copying of
parameter sets via
bus
Adjustment of source and
target set via keyboard
0
✳
Fr
·
0
1
✳
Fr
·
0
2
✳
Fr
·
0
3
✳
Fr
·
0
4
✳
Fr
·
0
5
✳
Fr
·
0
6
✳
Fr
·
0
7
✳
Fr
·
0
▲
DOWN
UP
▼
Choice of target set
At blinking dot behind the parameter
set number the target set 0…7 is
adjusted with the keys UP/DOWN.
During copying the active (A)
parameter set may not be adjusted
as target set If the target set is > 0,
only the programmable parameters
are overwritten!
A
✳
Fr
·
0
1
2
3
4
5
6
7
▲
DOWN
UP
▼
Choice of source set
With the keys UP/DOWN the initialization
set, default set or set 0…7 are choosen.
- At „init“ all parameters in every set are
overwritten with the factory setting.
- At „def“ the target set is overwritten with
the factory setting.
- At „0...7“ the selected parameter set is
copied into the target set. If the set is > 0,
only the programmable parameters are
copied into the target set.
0
def
init
➱
Changeover to source
➱
with Funct.
Starting of copying
If the source set is selected, the copying process can be started with „ENTER“. If the
copying process has been sucessfully completed the display shows „Pass“, otherwise
the message „nco“ (no copy) appears.
By loading the factory setting
all definitions defined by the
machine builder are reset!
This can include the terminal
assignment, set changeover or
operating conditions. Prior to
loading the initialization or default
set make sure that no unintended
operating conditions occur.
If the target set is on „current set“
no parameter values can be
changed, no copying processes
be started and no Drive Mode be
activated.