![KEB COMBIVERT F4-C Applications Manual Download Page 132](http://html1.mh-extra.com/html/keb/combivert-f4-c/combivert-f4-c_applications-manual_3852415132.webp)
6
4
KEB COMBIVERT F4-C
16
Name: Basis
28.01.98
©
KEB Antriebstechnik, 1997
All Rights reserved
Functional Description
Set Value and Ramp Adjustment
Chapter
Section
Page
Date
The different ramp functions can be adjusted separately for every frequency change
(acceleration forward, deceleration forward and so on). The selection is made with
oP.10 and is adjustable separately in each set. The function is activated after pressing
„ENTER“. In case of several selections the sum of the values must be entered:
Ramp
Bit-No
Value
Mode
Reference frequency
0 or 2
const. ascent
100 / 200 / 400 Hz
Acc.
0 + 1
1
const. time (B)
actual set value
forward
3
*const. time (V)
last set value at constant run
0 or 8
const. ascent
100 / 200 / 400 Hz
Dec.
2 + 3
4
*const. time (B)
actual set value
forward
12
const. time (V)
last set value at constant run
0 or 32
const. ascent
100 / 200 / 400 Hz
Acc.
4 + 5
16
const. time (B)
actual set value
reverse
48
*const. time (V)
last set value at constant run
0 or 128
const. ascent
100 / 200 / 400 Hz
Dec.
6 + 7
64
*const. time (B)
actual set value
reverse
192
const. time (V)
last set value at constant run
* Do not adjust these values
If the mode constant time is activated for a ramp, then the s-curve function is
deactivated for this ramp. The ascent is limited to minimum 100 Hz / 300 s.
Ramp Mode (oP.10)
delta_f
konstant
delta_t
delta_f
konstant
delta_t
delta_f
konstant
delta_t
delta_f_2
variabel
delta_t
delta_f_1
variabel
delta_t
t_rampe
t_1
f_1
t
t_2
f_2
f_soll
100 Hz
Picture 6.4.6.h
Graph with ramp modes
f_set