35
INSPEcTIONS PrIOr TO STArT-UP Of THE BrAKE
6.1.3.1 Function running-in
Application: First run-in at the customer, 100 % run-in at KEB.
Device size
01
02
03
05
06
07
08
09
10
11
12
Slip time
t
/ s
1
Idle time
t
/ s
1
0.5
Speed
n
/ rpm
25
Switching
cycles
20
15
Table 7:
Function running-in
6.1.3.2 Maintenance running-in
Application: Brake recovery due to unfavorable operating conditions.
Device size
01
02
03
05
06
07
08
09
10
11
12
Slip time
t
/ s
1
Idle time
t
/ s
1
0.5
Speed
n
/ rpm
25
Switching
cycles
3
Table 8:
Maintenance running-in
A maintenance interval of 4 weeks is recommended for normal industrial ap-
plications.