![KEB COMBILINE E6 Series Instructions For Use Manual Download Page 13](http://html2.mh-extra.com/html/keb/combiline-e6-series/combiline-e6-series_instructions-for-use-manual_3834107013.webp)
Technical data | 4
ma_dr_e6-hf-filter-nb-20337731_en
13
4 Technical data
4.1 Operating conditions
4.1.1 Climatic ambient conditions
Storage
Standard
Class
Notes
Ambient temperature
1K4
-25…55 °C
Relative humidity
1K3
5…95 % (without condensation)
Storage height
-
-
Transportation
Standard
Class
Notes
Ambient temperature
2K3
-25…70 °C
Relative humidity
2K3
95 % at 40 °C (without condensation)
Operation
Standard
Class
Notes
Ambient temperature
3K3
5…40 °C (extended to -10…45 °C)
Relative humidity
3K3
5…85 % (without condensation)
Site altitude
-
-
From 1000 m, a power reduction of 1 % per 100
m must be taken into account.
4.1.2 Mechanical ambient conditions
Storage
Standard
Class
Notes
Vibration limit
1M3
Vibration amplitude 3.0 mm (2…9 Hz)
acceleration amplitude 10 m/s² (9…200 Hz)
Shock limit values
1M3
100 m/s²; 11 ms
Transport
Standard
Class
Notes
Vibration limits
2M1
Vibration amplitude 3.5 mm (2...9 Hz)
Acceleration amplitude 10 m/s² (9...200 Hz)
Shock limit values
2M1
100 m/s²; 11 ms
Operation
Standard
Class
Notes
Vibration limits
3M4
Vibration amplitude 3.0 mm (2...9 Hz)
Acceleration amplitude 10 m/s² (9...200 Hz)
Vibration limit
-
Vibration amplitude 0.075 mm (10…57 Hz)
acceleration amplitude 10 m/s² (57…150 Hz)
Shock limit values
3M4
100 m/s²; 11 ms
4.1.3 Chemical/mechanical active substances
Storage
Standard
Class
Notes
Contamination gases
1C2
-
Contamination solids
1S2
-
Transportation
Standard
Class
Notes
Contamination gases
2C2
-
Contamination solids
2S2
-
Operation
Standard
Class
Notes
Contamination gases
3C2
-
Contamination solids
3S2
-