- 5 -
Descriptions of Component Parts
■
Main Parts and Descriptions
●
(
)
(
)
Front View
Back View
Operation Panel
Panel to operate a casting process.
Pressure Gauge
Indicates pressure inside of the muffle chamber.
Lock Arm
Used to lock the chamber lid and seal the muffle chamber.
Power Switch
with 20A breaker. In case of eddy current, shut it down immediately.
Dust Proof Filter
Used to prevent dust from entering the unit.
Muffle Chamber
Used to house furnace muffle to heat up and melt casting alloys.
Chamber Lid Handle
Used to manually open and close the chamber lid.
Note) Be gentle when you open and close the chamber lid. Quickly repeated movement will cause damage
to the unit.
View Glass
Used to protect eyes when checking melting alloy.
Vacuum Filter
Used to prevent dust in the chamber from entering the unit.
Eyebolt
Used to prevent the unit from falling down. Tie down the unit.
Air/Argon Switch Knob
Manual switch knob to choose between pressurized air or argon gas in applying
pressure for casting.
Compressed Air Filter
Used to prevent rust, dust, moisture etc. out of compressor from entering the unit.
Periodic cleaning is recommended.
Drain Cock
Cock to drain the moisture in the internal air tank.
Exhaust Filter
This is the exhaust filter of vacuum unit.
Operation panel
Air/Argon Switch Knob
CHILLER OUTLET
CHILLER
SIGNAL
ARGON
0.5-1.0MPa
WATER A WATER B
AIR IN
0.5-1.0MPa
DRAIN COCK
View Glass
Chamber Lid
Handle
Muffle Chamber
Dust Proof Filter
Power Switch
Lock Arm
Pressure Gauge
Drain Cock
Vacuum Filter
Eyebolt
Eyebolt
Compressed Air Filter
Exhaust Filter
EXHAUST