6.4 Shutdown
1.
Pump off the tank contents.
2.
Shut off the inlet and discharge lines.
3.
Interrupt power supply and secure against unintentional start-up.
DANGER
Power supply not disconnected
Danger to life!
▷
Pull the mains plug and secure the pump against unintentional start-up.
4.
Drain the tank completely (e.g. by means of the hand diaphragm pump).
5.
After long idle periods:
Remove and clean rotating assembly 01-44.
Spray the hydraulic section with oil for preservation.
6.
Unscrew hand hole cover 160.
7.
Clean the tank.
WARNING
Fluids handled and supplies posing a health hazard
Hazard to persons and the environment!
▷
Decontaminate lifting units which handle fluids posing a health hazard.
Wear safety clothing and a protective mask, if required.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
6 Commissioning/Start-up/Shutdown
34 of 86
mini-Compacta