Page 1: ... 3 INSTALLING THE DIDF Align the DIDF CON1 and CON3 over the interface headers on the drive The DIDF should easily drop down into the headers approximately 1 8 3 mm and the DIDF PC board should rest on all three clips To complete the installation of the DIDF press down firmly on the PC board near the three clips until the DIDF is secured onto the drive with all three clips FIGURE 2 INSTALLING THE ...

Page 2: ... Hz If the command from the master contains invalid parameters Address Quantity Function Code etc an exception response is sent back from the slave r Command Read Ox03 Normal Response Exception Resp_onse Slave Address Ox1E Slave Address Ox1E Slave Address Dx1E Function Code Ox03 Function Code Ox03 Function Code Ox83 Address High Ox07 Low OxOD Quantity High OxDO Low Dx01 CRC 16 Low Ox16 High DxD2 B...

Page 3: ...s Ox1E Function Code Ox90 Error Code Ox02 CRC 16 ILow OxFC IHigh Ox07 Slave Address This is the assigned Communication Station Number Function 10 00 The default setting is 30 decimal 1 E in hexadecimal Function Code This is the Modbus Function Code Report Slave ID Ox11 This Function reports the KBDF status RUN STOP and model specific information This command is primarily used with Drive Link Byte ...

Page 4: ...age In 60 Hz Mode Function 0 00 set to 0000 the drive output will be 230 Volts maximum for 230 Volt motors In 50 Hz Mode Function 0 00 set to 0001 the drive output will be 220 Volts maximum for 220 Volt motors Functions which can only be changed while the drive is in the Stop Mode FUNCTION GROUP 1 RUN STOP MODE Modbus Register Function No Description j_Ranqe Code Factory Setting 0100h 1 00 Run Sto...

Page 5: ...ion 0 0 10 0 0311h 3 17 Reserved 0312h 3 18 Fan Control 131 0000 Auto Run Temperature Control 0001 Run Mode Only 0002 Run Continuously 0003 Fan Off 0313h 0318h 3 19 3 24 Reserved Factory Setting 0000 0000 0000 0000 Factory Setting 5 00 0 00 60 0 50 0 1 5 1 5 0 0 00 0 00 0 00 0000 6 0 0000 7 0 0000 5 0 0000 Notes 1 When the dnve IS set for 50 Hz motors Funct1on 0 00 set to 0001 the Upper Frequency ...

Page 6: ... above the setting in Function 5 03 plus the setting in Function 5 04 5 The Load Loss Threshold function is not functional during acceleration deceleration or Stop Mode FUNCTION GROUP 6 DRIVE STATUS AND RESET Modbus Reqiste Function No Description RariqeiCode Factory Settinq 0600h 6 00 Drive ID 0601h 6 01 Software Version 0602h 6 02 Drive Horsepower 0603h 6 03 Fault Loa 1 0604h 6 04 Fault Lo 2 060...

Page 7: ...Seconds 0 3 180 0 10 0 0711h 0721h 7 17 7 33 Reserved Note 1 Each of the 7 Mult1 Funct10n Inputs can be programmed for any of the respect1ve functiOn codes f oooo 0015 2 Preset Frequenc1es 1 7 are obtained by selecting a specific combination of 3 Multi Function Input Terminals The specific frequencies are programmed in Functions 7 07 7 13 3 The rate of change of the UP Control for frequency settin...

Page 8: ...0 14 Motor Frequency OAOFh OA12h 10 15 10 18 Reserved FunctiOns which can only be changed while the dnve ISm the Stop Mode Read only 11 00 11 13 FUNCTION GROUP 12 RESERVED FUNCTIONS Modbus RegisteM Function No IDescription IRange Code IFactory Setting I OCOOh OC09h I 12 00 12 09 IReserved 1 I SAFETY WARNING Please read carefully before proceeding This product must be installed and serviced by a qu...