KAZE APPLIANCES SNP100 Instructions Download Page 1

VENTILATION FAN

WARNING

Models:  SNP100     SNP100L9

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the 

manufacturer at the address or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting 

means to prevent power from being switched on accidentally. When the service disconnecting means 

cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all 

applicable codes and standards, including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of 

fuel burning  equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline 

and safety standards such as those published by the National Fire Protection Association (NFPA), and 

the American Society for Heating, Refrigeration and Air Conditioning  Engineers (ASHRAE), and the 

local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.

7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - 

protected branch circuit (ceiling installation only).

8. This unit must be grounded.

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS 

PRODUCT IN A WALL.

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

4. Please read specification label on product for further information and requirements. 

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting 

brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the 

motor with the exact service motor. The impeller should also be replaced.

See “CONNECT ELECTRICAL WIRING” for details.

Cod: 0060300000-A

Summary of Contents for SNP100

Page 1: ...rotection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circuit Interr...

Page 2: ...anger bar a Hold the housing so that it is in contact with the bottom of the joist b Attach the housing with four 4 screws to the joist through the holes in each mounting flange a Slide one hanger bar into the channel on the housing and adjust as needed to fit between framing b Hold housing in place so that the housing contact the bottom of the joist Screw housing to joist through the hole of the ...

Page 3: ... a Install duct from the inside of the housing Fix the duct by the tab b Fix the BLOWER ASSEMBLY to the housing by 3 screws RETROFIT INSTALLATION 1 Remove wire panel and blower assembly before installation 2 Fold mounting ears flat against housing Blower assembly Wire panel 3 Enlarge ceiling opening to 9 1 2 by 9 1 2 leave ductwork and wiring in place 4 Connect wiring according to the wiring diagra...

Page 4: ...rt beyond the initial 12 month period This warranty does not extend to fluorescent lamp starters and tubes THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies This warranty does not cover inci...

Reviews: