background image

OPERATION    MANUAL

                                                              Thank you very much for purchasing our product.
Before using your unit, please read this manual carefully and keep it for future reference.

Data Converter 

CWC 15

Operation  Manual 

Summary of Contents for CWC 15

Page 1: ...OPERATION MANUAL Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference Data Converter CWC 15 Operation Manual...

Page 2: ......

Page 3: ...autions that should be brought to your attention during operation In order to ensure correct service of the wired controller please read this manual carefully before using the unit For convenience of...

Page 4: ...Table of Contents I Safety Precautions 1 II Installation and Operation of the Data Converter 3 III APP Function Description 12 IV Web Client Operation 37 V Remote Web Client Operation 38...

Page 5: ...e following contents identifiers and icons read the text body and observe the following rules Identifier description Identifier Meaning Means improper handling may lead to personal death or severe inj...

Page 6: ...ion performed by the user without permission may cause fire electric shock personal injury or water leakage Delegate installation Warning Forbid Forbid Do not spray flammable aerosol to the wire contr...

Page 7: ...r conditioning system via App or Web client The data converter is connected to the XYE bus of the air conditioner via port 485 of the air conditioner The power supply is connected to the mains supply...

Page 8: ...d to the data converter in hand in hand manner To use one LAN cable to connect multiple CWC15 gateways associate CWC15 gateways with one router For the configuration see section 3 1 4 Fig 2 2 Schemati...

Page 9: ...5 2 Hardware instruction Fig 3 1 Structure dimension drawing...

Page 10: ...6 Fig 3 2 Connect to the Ethernet communication terminal 485 terminal Power supply terminal RESET Status indicator light input Voltage DC5V...

Page 11: ...king box to see if the accessories are all in readiness Data converter is shown as the following figure Name Qty Outline 1 1 1 1 Data Converter Installation operation manual Power adaptor Wiring 3 ter...

Page 12: ...network communication indicator When it flashes it indicates that the data converter is accessing the Ethernet When it is off it indicates that the data converter is not accessing the Ethernet In thi...

Page 13: ...WER When the indicator flashes it indicates that an air conditioner is connected When it flashes it indicates that the data converter is accessing the Ethernet Power supply of the system is normal 9 A...

Page 14: ...set a static IP address for the data converter log in to the embedded Function list of App client CWC15 list CWC15 management Account management Group management Logs Temperature unit Log out 10 Web p...

Page 15: ...scheduled operations Operation logs operation logs User group group management 11 APP download IOS Go to APP Store seach M control or type http www aircontrolbase com login html to download the app An...

Page 16: ...r must enter the registration code as shown in the following figure Open App client on the smart phone Enter the registration code such as Systemair which is the first step Then click OK A login inter...

Page 17: ...ount can also be used to log in to the App and Web clients Procedure 13 Click Register Enter a valid email account and password The account information is generated on the cloud platform After registr...

Page 18: ...ience function is used for showing the main interface AC control booking control and so on Operation only available for choosing the unit of the temperature and setting the AC the other menu and funct...

Page 19: ...Refer to the guide to connecting the CWC15 and port XYE of the outdoor unit Connect the CWC15 to the router After login via App the main interface prompts the user to configure the CWC15 as shown in...

Page 20: ...guration Select one and the system counts down After configuration succeeds it goes to the main interface for displaying devices 2 1 Using a Network Cable Only when the following conditions are met ca...

Page 21: ...il all the CWC15 devices are configured Note When one LAN accesses multiple CWC15 gateways IP addresses of these gateways are displayed as shown in In this case one to one correspondence between the C...

Page 22: ...to the device configuration interface 2 Click Scan QR code It goes to the QR code scanning interface Scan the QR code shared with other users to complete configuration Note When the CWC15 is configure...

Page 23: ...ding an area Click as circled in the figure above On the displayed interface click Add Area Enter the name of the new area in the text box Click Save 3 Editing an Area 3 1 Adding and Deleting an Area...

Page 24: ...Deleting an area On the selected area slip left Click Delete to delete the area Click Edit to edit the area name 20...

Page 25: ...After an area is added it goes back to the area display interface Click the area to which a device is added Click Add Device Select the device to be added Click OK 3 2 Adding a Device to an Area 21...

Page 26: ...upper right corner as shown in the figure above Click Device management The device management interface is displayed Click Add Device indicated by to add a device or Remove Device to delete a device...

Page 27: ...istinguishing device states by using different colours This area displays the air conditioners in different states by using different colours as shown in the following figures Screening device states...

Page 28: ...wing Items to be locked Area list It displays area name the number of running air conditioners in the area and the total number of the air conditioners in the area Area colours A blue area indicates t...

Page 29: ...a control interface ambient temperature is not displayed The user can set temperature between 17 C and 30 C 62 F and 86 F and select a fan speed low medium high and auto Locking The user can lock mode...

Page 30: ...trol Power on or off Set temperature between 17 C and 30 C 62 F and 86 F Note If an air conditioner fails the main interface displays the fault and the user cannot operate the interface As shown in th...

Page 31: ...ten models are available Duct Four way Cassette Compact Four way Cassette One way Cassette Two way Cassette Wall mounted Ceiling Floor Floor Standing Fresh Air Proc and HRV It is an interface for rena...

Page 32: ...eduled Control Function Displayed in a chart Displayed in a list Click the icon indicated by The scheduled operation interface is displayed Scheduled operations can be displayed in a chart or in a lis...

Page 33: ...Inviting and Removing a User Select a CWC15 device from the list and then click Group Management The following interface is displayed Time Time Temperature Mode Fan speed Week Week Repeat or not Choo...

Page 34: ...ser If a QR code is displayed a user can scan it to join the user group The QR code is valid within 30 minutes Up to 10 users can join one user group Remove User Click it to remove a user from a user...

Page 35: ...ission Management The figure above shows all the permissions of the members in a user group Invite Re move users Change device information Device control Area control Lock function and View operations...

Page 36: ...Device Operation Record Device Log Login Record 7 Operation Logs Click Operation logs on the left The Operation logs interface is displayed as shown in the following figure 32...

Page 37: ...Device Logs Device logs include status logs and malfunction logs Status Log It displays gateway name time and status Malfunction Log It displays device number malfunction occurrence time and error cod...

Page 38: ...7 2 Device Operation Records The Device Operation Record displays operation records of each device including mode operation time user name and execution status 34...

Page 39: ...ords Login records are classified into App login records and Web login records APP It displays login user name and login time via the App client Web It displays login user name and login time via the...

Page 40: ...displayed as shown in the following figure Click the user name The Rename dialog box is displayed Enter a new name and then click Save Click Change Password On the Change Password interface enter the...

Page 41: ...type the IP address of the CWC15 gateway into the browser s address bar The embedded Web page of the CWC15 gateway is displayed Click Config to edit the IP address of the CWC15 gateway The IP address...

Page 42: ...box and password in the Password text box Click Login An account can only be registered on the App client Only after the account is activated can it be used for login on the Web client The frame selec...

Page 43: ...39...

Page 44: ...list It displays a list of CWC15 gateways configured via the App client Up to 10 gateways are supported It is an area display pane It displays areas and the air conditioners in an area setting include...

Page 45: ...determines whether to enable swing mode Lock sets the item to be locked Set temperature sets temperature ranging from 17 C to 30 C 62 F to 86 F It displays an area name Click the icon to rename it App...

Page 46: ...e same as that of area control Refer to the area control function In single control mode the user can select the air conditioner model indicated by The area on the left displays air conditioners indic...

Page 47: ...lock and error The auto mode is included in the cooling mode AC states filer display display the filtered AC in a state which is from AC systems and different area For example click Fan to filter the...

Page 48: ...led operation type device scheduled time mode temperature fan speed week and repeated or not Click Delete to delete a scheduled operation Click Edit to edit a scheduled operation Click Add to add a sc...

Page 49: ...eed and week and determine whether to repeat this scheduled operation 2 Timer shutdown On this tab page set scheduled time device week and determine whether to repeat this scheduled operation 5 Logs L...

Page 50: ...displayed on the Operation Record tab page are the same as those displayed on the App client including mode time user name and execution results 5 2 Status Logs The Status Log tab page displays online...

Page 51: ...5 3 Malfunction Logs The Malfunction Log tab page displays malfunction information and error codes 5 4 Login Records Both App Login Record and Web Login Record tab pages list login information 47...

Page 52: ...sts users Click it to set permissions It is a device management area Click it to delete a user group 6 1 Modifying User Permissions The administrator selects any member from a user group Click the Per...

Page 53: ...6 2 Renaming a User Group Click Rename to rename the selected user group 6 3 Inviting a User Click QrCode to generate a QR code of the user group Up to 10 users are supported 49...

Page 54: ...lick Ungroup to delete the selected user group 50 7 setting Click to enter into the setting interface modify unit of temperature Celsius Fahrenheit set supported languages English French and Spanish m...

Page 55: ......

Page 56: ...16110800000207 Version CCM15 PM 1 HW...