5.8.2
Connecting the interface cable to SFP+ Module
In order to properly connect the fiber optic cables, the following steps must be taken:
1.
Remove the protective dust plugs from the fiber-optic cable connectors.
2.
Preform the connection according to the instructions below:
a.
Link 0 of the system must be always connected as controls are delivered with this port.
b.
A fiber cable should match an SFP+ type.
c.
Both the TX and RX fiber cables must be connected between TX output (Marked with TX or Arrow
outwards the SFP+) on the JetCam camera and RX input (Marked with RX or Arrow inwards the SFP+)
on your Frame Grabber device.
d.
If more than a single cable is used to connect to the same Frame Grabber, the cables must be of the
same type and length.
3.
Insert the fiber cable into the module.
4.
Firmly push on each cable, until you will hear a click.
5.
Connect the other side of the fiber cables to your Frame Grabber device.
Note: Additional connectivity option is available using Fiber QSFP+ to SFP+ Breakout cable.
Figure 8 – Connecting the SFP+ cable
5.8.3
Removing the SFP Module
In order to remove the SFP+ module, follow these steps:
1.
Turn the JetCam camera off.
2.
Disconnect and remove all interface cables from the ports.
3.
Open the bale clasp on the SFP+ module with your index finger, or a small flat-blade screwdriver, in a
downward direction.
4.
Grasp the module between your thumb and index finger and carefully remove it from the port.
5.
Insert the clean dust covers into the module.
Figure 9 – Opening the bale clasp of an SFP+ Module