background image

Distributed by:

KaVo Dental GmbH
Bismarckring 39
88400 Biberach
Germany
Phone +49 (0) 7351 56-0
Fax +49 (0) 7351 56-1488

Manufacturer: 

KaVo Dental GmbH
Bismarckring 39
88400 Biberach
Germany
www.kavo.com

Summary of Contents for FLEXspace 5200

Page 1: ...Instructions for use FLEXspace Typ 5200 5200 U 5210 5210 U...

Page 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 88400 Biberach Germany Phone 49 0 7351 56 0 Fax 49 0 7351 56 1488 Manufacturer KaVo Dental GmbH Bismarckring 39 88400 Biberach Germany www kavo com...

Page 3: ...cal Data 12 3 3 Rating plate 14 4 Installation 16 4 1 Location 17 4 2 Mounting and connecting the FLEXspace 18 4 2 1 Recommended height setting 18 4 2 2 Connection of media single workstation 20 4 2 3...

Page 4: ...C Safety checks IEC International Electrotechnical Commission RI Repair instructions RK Retrofitting kit AS Assembly kit CK Conversion kit EP Enclosed parts EMC Electromagnetic compatibility PI Proces...

Page 5: ...per handling cleaning or maintenance non compliance with operating maintenance or connection instructions corro sion contaminated media supply or chemical or electrical influences deemed abnormal or i...

Page 6: ...ge on the delivery receipt The recipient and the representative of the shipping company must sign this delivery receipt 2 Leave the product and packaging in the condition in which you received it 3 Do...

Page 7: ...on delivery proceed as follows 1 Report any damage to the shipping company immediately and no later than 7 days after delivery 2 Leave the product and packaging in the condition in which you received...

Page 8: ...to prevent personal injury and material damage The warning notes are designated as shown below DANGER In cases which if not prevented directly lead to death or severe in jury WARNING In cases which if...

Page 9: ...vice the KaVo product Technicians of KaVo branch offices after appropriate product training Specifically KaVo trained technicians of KaVo franchised dealers KaVo shall not be responsible for damage ca...

Page 10: ...d permissible dust loads for workplaces Comply with the safety data sheets during any aspiration of hazardous ma terials Wear personal protective clothing during any aspiration of hazardous ma terials...

Page 11: ...Check the FLEXspace workstation for completeness FLEXspace single workstation Mat no 1 002 3459 The basic unit consists of 8 8 x20 4x25 1 2 3 4 5 Basic element Rear wall complete including 2 x inner...

Page 12: ...rder safety Bunsen burner tube 0 650 3741 from Accessories Worktop laminate straight with socket strip Mat no 1 002 4142 Waste drawers 2 x 50 Container 222 Mat no 1 002 3482 country specific power sup...

Page 13: ...e fluctuations 10 Power consumption max 12 A UL version Power rating of the socket strip max 12 A CAUTION Overloading of electrical cables Electrical shock The total power of the connected electrical...

Page 14: ...issible in enclosed rooms Permissible ambient temperature range from 5 C to 40 C Permissible relative air humidity max 80 Max elevation for operation max 2 000 m 3 3 Rating plate GAS DIN DVGW Site for...

Page 15: ...s for use FLEXspace Typ 5200 5200 U 5210 5210 U 3 Description of the product 3 3 Rating plate GS mark For disposal instructions see intended use Read and take note of the content of accompanying docum...

Page 16: ...ergency stop switch and an all pole safety disconnection device within reaching distance DANGER Errors during connection of gas lines and electrical cables Life threatening hazard All gas connections...

Page 17: ...rical connections The room illumination should be equivalent to daylight Operating the technical workstation in accordance with its intended purpose is possible if the requirements of EN 61010 1 are m...

Page 18: ...945 820 845 870 895 920 945 1 Level Upper edge AP without level compensation Body height I 820 mm 32 3 155 cm II 845 mm 33 3 156 163 cm III 870 mm 34 3 164 171 cm IV 895 mm 35 3 172 179 cm V 920 mm 3...

Page 19: ...Instructions for use FLEXspace Typ 5200 5200 U 5210 5210 U 4 Installation 4 2 Mounting and connecting the FLEXspace M8x12 M8 3 4 19 38...

Page 20: ...h side panel see Installation instructions 1 002 6461 for three unit workstation now attach side panels for shelves 3 unit Standard see Installation instructions 1 002 6457 3 unit Round see In stallat...

Page 21: ...Mounting and connecting the FLEXspace 4 2 3 Connection of gas single workstation Gas M5 GAS DIN DVGW 4 2 4 Connection of air single workstation Luft GAS DIN DVGW 4 2 5 Connection of electric componen...

Page 22: ...inal cross section Types 5200 5210 min 1 5 mm Types 5200 U 5210 U AWG 14 Temperature range 0 min 70 C Voltage resistance min 2 500 V AC max length 6 m Cable type Types 5200 5210 H05VV Types 5200 U 521...

Page 23: ...onnecting the FLEXspace CAUTION Connect the equipotential bonding conductor Connect the protective conductor safely to the electrical installation at cus tomer premises 4 2 6 Connection of gas 3 unit...

Page 24: ...s for use FLEXspace Typ 5200 5200 U 5210 5210 U 4 Installation 4 2 Mounting and connecting the FLEXspace 24 38 4 2 8 Connection of electrical components 3 unit workstation Elektrik 3 2 1 4x25 4x25 GAS...

Page 25: ...Instructions for use FLEXspace Typ 5200 5200 U 5210 5210 U 4 Installation 4 2 Mounting and connecting the FLEXspace GAS DIN DVGW M5x40 4x 7 G A S DI N DV GW 4x M5x10 M5x10 4x 8 25 38...

Page 26: ...r 3 unit workstation now attach connecting angle 3 unit Standard see Installation instructions 1 002 6457 3 unit Round see Installation in structions 1 002 6456 3 unit Star see Installation instructio...

Page 27: ...Instructions for use FLEXspace Typ 5200 5200 U 5210 5210 U 4 Installation 4 2 Mounting and connecting the FLEXspace M5x30 1x G AS DIN DVG W 3x25 10 M5x30 6x GAS DIN DVGW M5x40 2x 3 11 27 38...

Page 28: ...Instructions for use FLEXspace Typ 5200 5200 U 5210 5210 U 4 Installation 4 2 Mounting and connecting the FLEXspace 28 38 M5x35 6x 3 GAS DIN DVGW 12 GAS DIN DVGW 13...

Page 29: ...e Taking out compressed air To do this press on the side of the pneumatic hand held nozzle Regulating the flow rate To do this increase or reduce the pressure Setting the maximum flow rate To do this...

Page 30: ...arse dirt should be removed once a day with a scraper and then clean the workplace with a damp cloth and soap or similar 6 2 Caring for the work surface Care products Mat no 04119080 for Rockdent Once...

Page 31: ...pervision After use the gas supply must be cut off immediately either by closing the gas connection valve or by disconnecting the safety gas valve In training rooms gas systems may only be started up...

Page 32: ...worktop Mat no 1 002 4141 Side panel metal incl decor Mat no 1 002 4955 or Side panel metal without decor Mat no 1 002 3820 Drawer optional Mat no 1 002 3512 FLEXspace light LED Mat no 1 011 8864 Work...

Page 33: ...5x30 M5 4x15 0 b 0 b e n e n M4x30 1 2 3 4 Assembly variations in functional cell Waste drawer 2 x 50 Waste drawer 20 30 50 Suction panel waste drawer 50 or Waste drawer 20 and 30 Suction panel with...

Page 34: ...use FLEXspace Typ 5200 5200 U 5210 5210 U 8 Spare parts 34 38 8 Spare parts GAS DIN DVGW 1 002 2676 1 002 8733 0 653 9782 1 002 2685 0 653 1923 Set R2 3 1 003 0983 1 002 2656 1 002 2563 1 002 2591 Se...

Page 35: ...Instructions for use FLEXspace Typ 5200 5200 U 5210 5210 U 9 Declaration of conformity 6 3 Maintenance of the safety hose for the bunsen burner 9 Declaration of conformity 35 38...

Page 36: ......

Page 37: ......

Page 38: ...1 002 4316 Fk 20210902 4 en...

Reviews: