5 Startup | 5.1 Connector
5 Startup
Note
The ELECTROmatic may be operated exclusively with the
INTRA LUX KL703 LED motor (
Mat. no. 1.007.0150
), the COMFORTdrive
motorised contra-angle handpiece and the type 4882 power supply.
5.1 Connector
5.1.1 Connection conditions
NOTICE
Property damage due to incorrect pressures.
Property damage to motor or handpiece.
▶
Set the pressures according to the technical specifications.
NOTICE
Property damage due to bad media.
Property damage to motor or handpiece.
▶
Make sure that the compressed air is dry and free of dirt and oil according
to EN ISO 7494-2.
▶
Make sure that the pH of the water is between 7.2 7.8.
Note
If the water is very hard (above 12 °dH), a water softening device must be
fitted in the ion-exchange process.
Insufficient water hardness (below 8.4 °dH) can promote the formation of al-
gae.
Note
Use filters, water separators or air dryers according to need.
Air and water requirements according to DIN EN 7494-2
The compressed air must be free of oil, dirt, and contamination. If needed:
▪ Use a compressor with a dry air system.
▪ Include an upstream air filter (on the compressor), if applicable.
▪ Blow out the lines before connecting them.
5.1.2 Connecting the ELECTROmatic
NOTICE
Property damage due to soiled water lines.
Property damage to the product.
▶
Make sure that the water filter does not get clogged by soiled water.
▶
For this purpose, rinse the turbine hose for at least 1 minute before con-
necting its free end to the product in order to remove any soiled water from
the lines.