background image

1 / 8

ESO 126

26910036

ESO 129

26910058

Feed arm heaters for CAS 124/CAS 180

Features

About these instructions

This document is part of the product. These instructions 

describe how to install and connect the ESO 126 and ESO 129 

feed arm heaters.

 

▶ Do not install and use the device until you have read and 

understood this document.

 

▶ Keep this document for reference throughout the life of the 

device. Pass this document on to any subsequent owners 

and users.

The latest version of these instructions for use can be found on 

our website: 

www.kathrein-ds.com

Scope of supply

ESO 126

 

1 x PA corrugated hose, 0.84 m

 

1 x heater strip, 1.68 m

 

1 x rubber hose conductor 1 mm

2

, 3.3 m

 

1 x self-adhesive aluminium film, 5 m

 

English instructions for use

Transport and storage

 

▶ If possible, transport and store the feed arm heater in the 

original packaging.

 

▶ Store the feed arm heater in a dry location and protect it 

against mechanical damage.

The heaters each consist of a self-limiting heater strip, which 

is U-shaped and attached to a support hose. The heater strip is 

provided with a light current cable length 3.3 m for connection 

to the controllers ESO 96 S, ESO 97 S, ESO 97 SL or ESO 99 S.
The heaters are intended for the feed arms ZAS 124C and ZAS 

181C of the parabolic antennas CAS 124 and CAS 180 and fit 

within the 42 x 42 mm clear internal dimension of the support 

tube.

ESO 129

 

1 x PA corrugated hose, 1.38 m

 

1 x heater strip, 2.76 m

 

1 x rubber hose conductor 1 mm

2

, 3.3 m

 

1 x self-adhesive aluminium film, 5 m

 

English instructions for use

The scope of supply is a fully assembled item ESO 126 or ESO 129.

 

You can download an English version of this user 

manual from our homepage.

Summary of Contents for ESO 126

Page 1: ...se Transport and storage If possible transport and store the feed arm heater in the original packaging Store the feed arm heater in a dry location and protect it against mechanical damage The heaters each consist of a self limiting heater strip which is U shaped and attached to a support hose The heater strip is provided with a light current cable length 3 3 m for connection to the controllers ESO...

Page 2: ...shock in the event of contact with electrical equipment Correct performance of the installation and electrical connection is a crucial safety factor Observe the installation conditions and steps described as precisely as possible Modifications to the electrical installation may only be carried out by a specialist electrician Do not make any modifica tions yourself Intended use Do not use the ESO 1...

Page 3: ... of the heater within the support tube Electrical connection 1 Feed the connection cable of the feed arm heater into the terminal box of the controller and secure it with cable ties The cable is then threaded through the cable gland M16 provided 2 Before connecting the cable to the controller check the insulation resistance Ri of the heater Heater no Target value Actual value Insulation resistance...

Page 4: ...4 8 Drawing of ESO 126 129 Winding direction of the aluminium foil from bottom to top Cable 3 3 m H05RNF3G 1 0 mm 90 840 1380 Heater strip ELSR H 60 2 BOT PA corrugated tube PG29 ...

Page 5: ...7 1R1 1 2 PT 100 11 ELTC 21 18 230 VAC SCH0000 ESO 97 S Outdoor temperature control with ELTC 21 K2 6 5 4 8 K1 9 ESO 180 H ESO 124 H Optional ESO 90 H ESO 120 H X1 1 E1 1 E1 2 4 3 E1 4 5 E1 PE 6 7 E1 8 ESO 126 ESO 129 Feed arm heaters for CAS 124 CAS 180 9 E1 10 PE 2 PE 3 PE 4 PE 5 PE 1 Temperaturfühler ...

Page 6: ...emperature control with 2 ELTC 21 K2 6 5 4 8 K1 9 1U3 10 17 1R2 Sensor Heating temperature 1 2 PT 100 11 ELTC 21 18 230 VAC K2 6 5 4 8 K1 9 ESO 180 HL Optional ESO 180 H ESO 124 HL Optional ESO 90 H ESO 120 H ESO 124 H X1 1 E1 1 E1 2 4 3 E1 4 5 E1 PE 6 7 E1 8 ESO 126 ESO 129 Feed arm heaters for CAS 124 CAS 180 9 E1 10 PE 2 PE 3 PE 4 PE 5 PE 1 Sensor Outdoor temperature ...

Page 7: ...D 6 5 14 13 10 K1 11 ESO 180 HL ESO 180 H Optional ESO 90 H ESO 120 H ESO 124 H X1 1 E1 1 E1 2 4 3 E1 4 5 E1 PE 6 7 E1 8 ESO 126 ESO 129 Beheizung für Speisesystem Halterungen 9 E1 10 PE 2 PE 3 PE 4 PE 5 PE 1 Sensor Heating temperature ESO 124 HL 1 NST 255 2 Stabsonde EL rosa GND grau 22 21 132 131 X1 Alarm Ruhestromprinzip im Fehlerfall geöffnet Fernwirkkontakt manuell Ein 5 30V weiss grün braun ...

Page 8: ...X1 N N L X2 L L PE X3 PE PE COM X4 NC NO 1 X5 2 3 K2 90 260 VAC ELTC 14 K1 Electronic equipment Electronic equipment must not be disposed of in domestic waste According to directive 2012 19 EU OF THE EUROPEAN PARLIAMENT AND COUNCIL of 04 July 2012 on waste electrical and electronic equipment it must be disposed of profes sionally At the end of its service life take this unit to a designated public...