background image

Putting into operation 

 

23 

Mains voltage  

Run the modem via the accompanying plug-in 
power adapter off a mains voltage of 230 V/50 Hz 
only. The unit must not be connected to the sup-
ply until after the connections to the antenna 
socket and the PC have been set up. 

Grounding 

The house distribution system must be grounded 
in accordance with the relevant local and/or Ger-
man VDE regulations. 

RF-connection 

Do not remove the cable connection (F-plug) from 
the modem while it is still connected to the mains 
supply. 

 

 

All manuals and user guides at all-guides.com

Summary of Contents for DCM 32

Page 1: ...tung Operating Manual Mode d emploi Kabelmodem Cable modem Modem câble DCM 32 DCM 42 42 I Bestell Nr Order No Référence 26210042 26210043 26210044 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...2 All manuals and user guides at all guides com ...

Page 3: ...nschlüsse 9 Aufstellungsort und Montage 10 Aufstellungsort 10 Lüftung 10 Feuchtigkeit 10 Sonneneinstrahlung Wärme 10 Netzspannung 11 Erdung 11 HF Anschluss 11 Installation 12 Voraussetzungen 12 Anschlüsse 12 Betriebsanzeigen und Fehlerdiagnose 14 Ausfall der Datenübertragung 14 Technische Daten 15 Downstream 15 Upstream 15 SNMP Management 16 Schnittstellen 16 Mechanische Daten 16 Umgebungsbedingun...

Page 4: ...ing into operation 22 Ventilation 22 Humidity 22 Exposure to sunlight heat 22 Mains voltage 23 Grounding 23 RF connection 23 Installation 24 Preconditions 24 Connections 24 Status indicators and Error diagnosis 26 Failure of data transmission 26 Specifications 27 Downstream 27 Upstream 27 SNMP management 28 Interfaces 28 Physical data 28 Ambient conditions 28 Scope of delivery 28 Connection scheme...

Page 5: ...é 34 Exposition au soleil à la chaleur 34 Tension d alimentation 35 Mise à la terre 35 Branchement RF 35 Installation 36 Conditions préalables 36 Raccordements 36 Affichages de service Diagnostique d erreur 38 Panne de la transmission de données Fehler Textmarke nicht definiert Caractéristiques techniques 40 Downstream 40 Upstream 40 Gestion SNMP 41 Interfaces 41 Caractéristiques mécaniques 41 Con...

Page 6: ...ihr Telefonanschluss bleibt weiterhin erreichbar Erschließen Sie sich das weite Tor zum Internet und genießen Sie mit nur einem Klick Videos und Musik oder holen Sie sich interessante Informati onen Data Over Cable Service Interface Specifications DOCSIS spezifiziert die Schnittstellenan forderungen an Kabelmodems für die Hochgeschwindigkeits Datenübertragung in BK Netzen EURODOCSIS Europäische DO...

Page 7: ...hlüsse und Anzeigen 7 Anschlüsse und Anzeigen LEDs Erklärung auf Seite 14 ff 1 2 3 4 1 Stromversorgung 12 V 2 HF Buchse F Buchse 3 Ethernet Buchse 4 USB Buchse All manuals and user guides at all guides com ...

Page 8: ...ten sie darauf dass das Stromversorgungs kabel nicht beschädigt wird Nehmen sie das Ge rät niemals mit defektem Netzkabel oder Ste ckernetzteil in Betrieb Verwenden sie aus schließlich das mitgelieferte Netzteil Reinigung Trennen sie das Modem vom Netz bevor sie es reinigen Benutzen sie zur Reinigung ein trocke nes Tuch Reinigen sie lediglich die Oberfläche Öffnen sie das Gehäuse auf keinen Fall B...

Page 9: ...geöffneten Gerät Anschlüsse Eine Fehlbeschaltung der Anschlüsse kann zu Betriebsstörungen oder zu Defekten am Gerät führen Elektronische Geräte gehören nicht in den Hausmüll sondern müssen gemäß Richtlinie 2002 96 EG DES EUROPÄISCHEN PARLA MENTS UND DES RATES vom 27 Januar 2003 über Elektro und Elektronik Altgeräte fachge recht entsorgt werden Bitte geben Sie dieses Gerät am Ende seiner Verwendung...

Page 10: ...auf eine geeignete ebene Unterlage Lüftung Die im Modem entstehende Wärme wird ausrei chend abgeführt Installieren sie es trotzdem niemals in einem Schrank oder einem Regal mit unzureichender Lüftung Der Freiraum nach oben sollte wenigstens 5 cm betragen Verschließen sie niemals die Kühlöffnungen des Gerätes Stellen sie keine Gegenstände auf das Modem Feuchtigkeit Schützen sie das Modem vor Feucht...

Page 11: ...ssen werden nachdem die Verbindun gen mit der Antennensteckdose und dem PC hergestellt wurden Erdung Die Hausverteilanlage muss entsprechend den einschlägigen örtlichen und oder VDE Vorschriften geerdet sein HF Anschluss Entfernen sie den Kabelanschluss F Stecker nicht vom Modem solange es am Stromnetz an geschlossen ist All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 12: ...uss ein Koaxial kabel mit Anschlusssteckern der Norm F Das Anschlusskabel muss CE konform ausge führt sein und ein Schirmungsmaß gemäß Class A von 85 dB aufweisen z B Kathrein ETG 15 ETG 30 Verbinden sie das Steckernetzteil mit dem Gleichspannungseingang 1 DC IN 12 V und mit dem Stromnetz Verwenden sie a den Ethernet oder b den USB Anschluss mit dem entsprechenden mitge lieferten Kabel a Verbinden...

Page 13: ...zeuge Ziehen sie die Stecker nur handfest an Sobald das Modem ordnungsgemäß angeschlos sen ist nimmt es den Betrieb auf Weitere Maß nahmen sind nicht erforderlich Es findet nun au tomatisch den Datenkanal meldet sich am Rech ner an und nimmt die Kommunikation mit dem Rechner auf Die notwendigen Informationen zur Konfiguration ihres PC und die Zugangsvoraussetzungen erhal ten sie vom Kabelnetzbetre...

Page 14: ...chtet grün kein HF Träger Downstream Trägersuche Downstream HF Träger Downstream vorhanden und Abstimmungsvorgang Anmeldevorgang Kabelmodem angemeldet und bereit für Datenübertragung PC dunkel leuchtet stetig grün blinkt kein Ethernet oder USB Signal Ethernet oder USB Signal vorhanden Datenübertragung zum PC Data dunkel blinkt grün kein Datenverkehr Datenübertragung zur Kopfstation Test dunkel leu...

Page 15: ...e schwindigkeit 42 Mb s 64 QAM 56 Mb s 256 QAM Fehlerkorrektur Reed Solomon ITU T J 83 Annex A Frequenzbereich 108 MHz bis 860 MHz Eckfrequenzen in 250 kHz Schritten Bandbreite 8 MHz Upstream Zugriffsverfahren TDMA S CDMA DOCSIS Modulation QPSK 8 16 32 64QAM 128QAM nur bei S CDMA Modulationsrate TDMA 160 320 640 1280 2560 und 5120 kHz S CDMA 1280 2560 und 5120 kHz Bandbreite TDMA 200 400 800 1600 ...

Page 16: ...aufnahme 9 W max Mechanische Daten Größe mm 200 x 132 x 32 B x T x H Gewicht g 660 ohne Netzteil Umgebungsbedingungen Betriebstemperatur 0 40 C Feuchtigkeit 10 90 nichtkondensie rend Lagertemperatur 20 60 C Lieferumfang 1 MCNS oder EURODOCSIS Kabelmodem 1 Ethernet Kabel 1 USB Kabel 1 Steckernetzteil 1 Satz Aufsteckfüße zur vertikalen Aufstellung des Modems 1 CD ROM mit USB Treibern 1 Bedienungsanl...

Page 17: ...sollten sie mit ihrem Modem wider Erwarten Probleme haben setzen Sie sich bitte mit ihrem zuständigen Kabelnetzbetreiber in Verbindung USB Kabel Ethernet Kabel Kabelanschluss Koaxkabel Netz 10BASE T RF DC IN USB All manuals and user guides at all guides com ...

Page 18: ... to the Internet at your disposal your telephone connection still remains accessible Open up the wide portal to the Internet and with just one click enjoy videos and music or simply fetch interesting information Data Over Cable Service Interface Specifications DOCSIS specifies the interface requirements on cable modems for high speed data transmission in BC networks EURODOCSIS European specificati...

Page 19: ...ays 19 Connections and displays LEDs Explanation on page 26 1 2 3 4 1 Power supply 12 V 2 RF input F socket 3 Ethernet socket Western 4 USB Series B socket 10BASE T RF DC IN USB All manuals and user guides at all guides com ...

Page 20: ...uipment connected to the modem Mains connection Make certain that the mains lead is undamaged Never put the unit into operation if the mains lead or plug in power supply is damaged Do not use any power supply other than the one supplied with the unit Cleaning Disconnect the modem from the mains before cleaning it Use a dry cloth for cleaning Clean the surface only On no account open the unit s hou...

Page 21: ... the unit is opened Connections Incorrect wiring up of the connections can result in operational failure or to defects on the unit Electronic equipment is not household waste in accordance with directive 2002 96 EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL of 27th January 2003 on used electri cal and electronic equipment it must be disposed of properly At the end of its service life take this uni...

Page 22: ...e smooth pad where necessary Ventilation The heat generated in the modem is dissipated quite adequately Nevertheless never install it in a cabinet shelf or rack with inadequate ventila tion The clearance above the unit should be at least 5 cm Never close off the openings on the unit intended for heat dissipation Do not place any objects on top of the modem Humidity Protect the modem against humidi...

Page 23: ...sup ply until after the connections to the antenna socket and the PC have been set up Grounding The house distribution system must be grounded in accordance with the relevant local and or Ger man VDE regulations RF connection Do not remove the cable connection F plug from the modem while it is still connected to the mains supply All manuals and user guides at all guides com ...

Page 24: ...xial cable with F type connector plugs The connecting cable must have CE confor mity and exhibit a shielding factor in compli ance with class A of 85 dB e g Kathrein ETG 15 ETG 30 Connect the power adapter to the D C volt age input 1 DC IN 12 V and to the mains supply Use a the Ethernet or b the USB connection a Connect the 10 100Base T Ethernet connec tions with one another Western socket of your...

Page 25: ...s connected properly it commences operation No further measures are required It now automatically finds the data channel logs on to the computer and com mences communication with the computer The necessary information for configuring your PC and the access preconditions can be obtained from your cable network provider or service pro vider All manuals and user guides at all guides com ...

Page 26: ...fast lit no RF carrier Downstream scanning for RF carrier Downstream downstream RF carrier present and ranging in progress registration in progress cable modem registered and ready for data transfer PC not lit lit flashing no Ethernet or USB carrier present Ethernet or USB carrier present data transfer to PC Data not lit flashing No data transfer Data transfer to cable headend Test not lit lit no ...

Page 27: ...hysical speed 42 Mb s 64 QAM 56 Mb s 256 QAM Error correction Reed Solomon ITU T J 83 Annex A Frequency range 108 MHz to 860 MHz edge frequencies in 250 kHz steps Band width 8 MHz Upstream Access method TDMA S CDMA DOCSIS 2 0 Modulation QPSK 8 16 32 and 64QAM 128QAM with S CDMA only Modulationsrate TDMA 160 320 640 1280 2560 und 5120 kHz S CDMA 1280 2560 and 5120 kHz Bandwidth TDMA 200 400 800 160...

Page 28: ...VDC Power consumption 9 W max Physical data Dimensions mm 200 x 132 x 32 W x D x H Weight g 660 without mains adapter Ambient conditions Operating temperature 0 40 C Humidity 10 90 non condensing Storage temperature 20 60 C Scope of delivery 1 MCNS DOCSIS cable modem 1 Ethernet cable 1 USB cable 1 plug in mains adapter 1 set off clip on feet to raise the modem vertically 1 CD ROM with USB drivers ...

Page 29: ...r In the unlikely event that you should experience problems with your modem please contact your relevant cable network provider USB cable Ethernet cable Cable connection Coaxcable Mains 10BASE T RF DC IN USB All manuals and user guides at all guides com ...

Page 30: ...t votre ligne téléphonique reste libre Ouvrez en grand la porte de l internet pour profi ter de clips vidéos et musicaux à portée d un clic de souris ou pour aller chercher des informations intéressantes Data Over Cable Service Interface Specifications DOCSIS est un ensemble de spécifica tions relatives au modem câble pour la transmission à vitesse élevée dans des réseaux à câbles large bande EURO...

Page 31: ...ts et affichages Voyants explication à partir de la page 35 1 2 3 4 1 Alimentation 12 V 2 Prise HF embase type F 3 Prise Ethernet Western 4 Prise USB 10BASE T RF DC IN USB All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 32: ... d alimentation Veillez à ce que le cordon d alimentation ne soit pas abîmé Ne mettez jamais en service l appareil si le cordon secteur ou l adaptateur secteur est abîmé Employez exclusivement l adaptateur sec teur livré avec l appareil Nettoyage Débranchez le modem du secteur avant de le nettoyer Utilisez un chiffon sec pour le nettoyer Ne nettoyez que la surface externe de l appareil N ouvrez en...

Page 33: ...enus à l utilisateur si l appareil était ouvert Raccordements Un mauvais branchement des câbles peut occa sionner des dysfonctionnements de l appareil ou l endommager Les appareils électroniques ne doivent pas être mis dans la poubelle de la maison mais doivent être recyclés correctement selon la directive 2002 96 EG DU PARLEMENT ET DU CONSEIL EUROPEEN du 27 janvier 2003 concernant les appareils é...

Page 34: ... un support approprié entre le modem et le meuble Aération Bien que l évacuation de la chaleur produite dans le modem soit suffisamment garantie n installez jamais le modem dans une armoire ou sur une étagère s il n y dispose pas d une ventilation suffi sante L espace libre au dessus du modem de vrait être au moins de 5 cm N obstruez jamais les ouvertures de ventilation de l appareil Ne posez pas ...

Page 35: ...re branché sur le secteur seulement après que les liaisons à la prise d antenne et au PC ont été effectuées Mise à la terre L installation de distribution individuelle doit cor respondre aux prescriptions locales en vigueur et ou à celles de l UTE Branchement RF Ne retirez pas le câble HF connecteur F du mo dem tant que le modem est branché sur le sec teur All manuals and user guides at all guides...

Page 36: ...our le raccordement un câble coaxial avec des connecteurs de type F Le câble de raccordement doit porter le mar quage CE et le facteur de blindage doit être selon la classe A 85 dB p ex ETG 15 ETG 30 de Kathrein Reliez l adaptateur secteur à l entrée tension continue 1 DC IN 12 V et au secteur Employez soit a la liaison Ethernet soit b la liai son USB avec le câble approprié livré avec l ap pareil...

Page 37: ...ès que le modem est correctement branché il se met en service d autres mesures ne sont pas nécessaires Il trouve automatiquement le canal de données contacte l ordinateur et établit une communication avec l ordinateur Les informations nécessaires pour configurer vo tre PC et les conditions préalables d accès sont disponibles auprès de l exploitant du réseau câblé ou du prestataire de services All ...

Page 38: ...quence Downstream Recherche pour porteuse Downstream Onde porteuse à radiofréquence Down stream existante et procédure d accord Ouverture de session Modem câble est annoncé et prêt pour la transmission de données PC foncé resplendit perma nent en vert clignote Aucun signal Ethernet ou signal USB Signal Ethernet ou USB existant Transmission de données à l ordinateur Data foncé clignote en vert Aucu...

Page 39: ...Affichages de service Diagnostique d erreur 39 All manuals and user guides at all guides com ...

Page 40: ... physique 42 Mo s 64 QAM 56 Mo s 256 QAM Correction d erreur Reed Solomon ITU T J 83 Annex A Plage de fréquence 108 MHz à 860 MHz fréquences limites par pas de 250 kHz Largeur de bande 8 MHz Upstream Méthode d accès TDMA S CDMA DOCSIS 2 0 Modulation QPSK 8 16 32 64QAM 128QAM avec S CDMA uniquement Vitesse de modula tion TDMA 160 320 640 1280 2560 et 5120 kHz S CDMA 1280 2560 et 5120 kHz Largeur de...

Page 41: ...max Caractéristiques mécaniques Dimensions mm 200 x 132 x 32 P x L x H Poids g 660 sans adaptateur secteur Conditions environnantes Température de service 0 à 40 C Humidité 10 à 90 sans condensation Température de stockage 20 à 60 C Fourniture standard 1 modem MCNS ou EURODOCSIS 1 câble Ethernet 1 câble USB 1 adaptateur secteur 1 jeu de pieds enfichables pour installer le mo dem en position vertic...

Page 42: ...re toute attente votre modem devait vous poser quelques problèmes veuillez contacter l exploitant du réseau câblé Câble USB Câble Ethernet Branchement au réseau câblé Câble coaxial Adaptateur secteur 10BASE T RF DC IN USB All manuals and user guides at all guides com ...

Page 43: ...Notizen 43 Notizen All manuals and user guides at all guides com ...

Page 44: ...Notizen 44 All manuals and user guides at all guides com ...

Page 45: ...31 184 0 Fax 49 8031 184 306 Anton Kathrein Straße 1 3 P O Box 10 04 44 D 83004 Rosenheim Germany 936 2456 C 0605 ZWT Technische Änderungen vorbehalten Subject to alterations Sous réserve de modifications techniques All manuals and user guides at all guides com ...

Reviews: