130
KATANA S610M Inverter Specialized for Elevator Manual
2. Cleaning
①
Keep the inverter clean;
②
Clear dust on the surface effectively to prevent dust from entering inside the inverter, especially the metal
dust;
②
Clear greasy dirt off the cooling fan effectively.
9.2 Periodical Maintenance
User can make a regular check every 3-6 months or by even shorter time according to the operation conditions, to
prevent the inverter from breakdown, and to guarantee its high performance for a longer time. Please check the
following:
1
.
Check if the working ambient temperature and humidity meet the standard requirements.
2
.
Make a thorough clean for the dust on the surface of PCB, wind channel, heat-sink, which is better to be
cleaned by dust collector.
3
.
Please check if the screws on the wiring terminals are fastened firmly. If they are loose, please fasten them
by the screwdriver; check if connectors or flat cables are loose or attached with any foreign matter.
4
.
Check if power cable and control cable are damaged, especially if there are any cut scratches in the wire
jacket which contacts with the metal surface; check if the insulation binder of the power cable nose peels off.
5
.
Check if poor connection of the main circuit terminal happens, and if the contact point of the copper platoon
is overheated.
6
.
Check if the controller is damaged, transformed, or corroded.
7
.
Check if there is any leakage, color change, crack or expansion of electrolytic capacitor.
8
.
Please check insulation of the main circuit.
Attention
:
Please detach the main circuit wire from the vector control unit when measuring
insulation resistance by megameter (DC, 500V). Never measure control circuit insulation by insulation
resistor.
9
.
Please check insulation of the motor.
Attention
:
Be sure to inspect the motor alone after the wire between the motor and the inverter is
completely disconnected. Otherwise, the inverter may be damaged.
9.3
Wearing Parts Replacement
The wearing parts mainly include cooling fan and electrolytic capacitor. Their service life is closely related with
application ambient and maintenance. The common working life is shown as below:
Parts Name
Service life