Page 32
Katadyn
15.6
Short Circuit
Short Circuit
Short circuit inside of the Activator or the wiring
to the Activator
•
Check if there is an short circuit form the Control Cabinet to the Activator or inside the
Activator
15.7
Communication Error
Communication Error
Connection between PLC and HMI is faulty
•
Check if the PLC is running without any fault (red LED) indication
•
Check the connection between PLC and HMI
•
Restart the PLC
Mains Switch OFF/ON
Summary of Contents for EK-24
Page 1: ...ELECTRO KATADYN INSTRUCTION MANUAL EK 4 EK 24...
Page 16: ...Katadyn Page 15 Change to the screen Alarm History Change to the screen Trend...
Page 37: ...Page 36 Katadyn 17 4 Dimensions EK 24 300 400 140 G 1 G 1 235 400 400 160 240 50 65...
Page 41: ...Page 40 Katadyn 17 6 2 EK 24 Anode brown Cathode blue EK Control Cabinet X1 1 2 br bl...
Page 42: ...Katadyn Page 41 18 CE declaration of conformity...