Katadyn
Page 9
8
Technical data
8.1
Operating data
Electro Katadyn
Type of device
EK-4
EK 2-24 EK 3-24 EK 4-24 EK 6-24
Application
Drinking water 0.02ppm
20m
3
/h 40 m
3
/h 60 m
3
/h 80 m
3
/h 120 m
3
/h
Cleaning Rinse water 0.5ppm
0.8 m
3
/h 1.6 m
3
/h 2.4 m
3
/h 3.2 m
3
/h 4.8 m
3
/h
Disinfected Cleaning water 1.0ppm
0.4 m
3
/h 0.8 m
3
/h 1.2 m
3
/h 1.6 m
3
/h 2.4 m
3
/h
Lifetime of the anode (est.)
20'000 m
3
(at 0.01 ppm Ag)
10'000 m
3
(at 0.02 ppm Ag)
Conductivity drinking water
100 to 500 µS/cm
Conductivity low
3 to 99 µS/cm
Chloride (Cl)
Max. 25 ppm
Organics (KMnO4)
Max. 10 ppm
Activator housing
No. of anodes of Type E1
1
2
3
4
6
Material of the body
1.4301 / 316S
Nominal pressure (bar)
6 / PN6
Weight (without water) kg
5.8
15.8
16.2
16.6
17.3
Dimensions
Height mm
500
605
Diameter mm
64
140
Connections (inlet / outlet)
G 3/4"
G 1"
Mounting position
Vertical
Control Cabinet
Dimensions mm (w x h x d)
300 x 400 x 155
Weight kg
9.8
Electrical supply
230/120V 50/60Hz
Nominal power
40W
Protection class
IP64
Remote Interface (see attachment 17.5)
6 Remote relay output:
4 Remote Input :
2 Analog Input:
Potential free relay contacts (max.240VAC/2A/24VDC)
Contact closed 24VDC from cabinet
0-10VDC
Summary of Contents for EK-24
Page 1: ...ELECTRO KATADYN INSTRUCTION MANUAL EK 4 EK 24...
Page 16: ...Katadyn Page 15 Change to the screen Alarm History Change to the screen Trend...
Page 37: ...Page 36 Katadyn 17 4 Dimensions EK 24 300 400 140 G 1 G 1 235 400 400 160 240 50 65...
Page 41: ...Page 40 Katadyn 17 6 2 EK 24 Anode brown Cathode blue EK Control Cabinet X1 1 2 br bl...
Page 42: ...Katadyn Page 41 18 CE declaration of conformity...