41 / 75
•
Insulate the gap between the door extension and the wall with fireproof mineral wool. Follow
the instructions of the mineral wool manufacturer! Do not cover the air openings in the upper
edge of the frame with wool. They are situated right behind the upper edge of the front
frame.
•
Install the covering frame in place to its screws.
•
Tighten the screws so that the lower edge of the covering frame is near the floor.
•
Push the door frame so that the covering frame goes well in its place against the wall and
fasten the door inside the tunnel with two screws.
2.5.3. Connecting from the back Saga PK
JK and KSIL stoves cannot be connected from the back of the chimney; they only have a flue
opening.
Make an opening into the brick chimney that is 2
–3 cm larger than the connection pipe. Remove
the plate covering the hole in the back mantle with a screwdriver. Put the cap covering the back
flue opening as the cap of the backmost hole on top of the stove. Put the connection pipe of the
stove into the back flue opening of the stove. Push the stove in place. Make sure that the
connection pipe goes well to the opening made in the chimney. Insulate the empty space
between the connection pipe and the chimney with flexible, fireproof material such as stone wool.
The lead-through is tidied up with a Kastor covering plate, which is available at hardware stores.
The covering plate is fastened to the brick chimney with metal brackets or fireproof paste.
2.5.4. Connecting from the top (all models)
Make an opening into the brick chimney that is 2
–3 cm larger than the connection pipe.
Use a bent pipe for the connection from the top of the stove, which can be turned to align with the
chimney. Suitable bent pipes are available at the hardware store. Extend the bent pipe with an
extension piece, if necessary. Install the stove’s own connection pipe in the flue opening on top
of the sto
ve. The bent pipe is then attached to the stove’s own connection pipe. Saw the bent
pipe and any extension pipe down to a suitable size where necessary. Make sure the pipe
extends sufficiently into the chimney (but not so far that it blocks up the chimney).
Seal the empty space between connection pipe and chimney with flexible, fireproof material such
as stone wool. The lead-through is then tidied up with a covering plate, which is available at your
hardware store. The covering plate is attached to the wall with metal bolts or fireproof paste.
2.6. Connecting to a Kastor or Helo chimney
The stove can be connected from the top to a factory built Helo chimney.
Make sure to choose the correct chimney type with regard to your stove mode, chimney height,
exterior circumstances, temperature class T 600 etc. For best results we recommend that you
install a chimney valve, as well.
•
Install a non-insulated connection pipe and any necessary extension piping on top of the
connecting pipe. Where necessary, saw the connection pipe and the extension pipe down
to suitable size.
•
The chimney valve goes between the insulated and no insulated sections or into the first
insulated pipe section.
•
Continue from the chimney valve with an insulated pipe. The insulated pipe section must
start at least 400 mm beneath the ceiling. Follow the chimney's installation and usage
instructions.
Remember to keep all safety distances to flammable and non-flammable materials named above.
Helo Oy does not guarantee the suitability and functionin
g of other manufacturers’ factory-built
chimneys with Helo and Kastor stoves. Helo Oy does not accept liability for the quality of other
manufacturers’ factory-built chimneys.
Summary of Contents for SAGA-20PK KSIL
Page 17: ...17 75 SAGA 20 27 PK PK JK ja PK KSIL Montering och bruksanvisning SAGA PK...
Page 33: ...33 75 SAGA 20 27 PK PK JK and PK KSIL models installation and usage manual SAGA PK...
Page 49: ...49 75 SAGA20 27 PK JK KSIL SAGA PK...
Page 51: ...51 75 KASTOR SAGA PK KASTOR Kastor Ceram 800 Coanda www helo fi...
Page 52: ...52 75 1 1 1 o o o o 2 o 1 2 1 3 3 2 2 25 2 2 T 600 o C 2 3 2 4...
Page 53: ...53 75 17 120 Kastor...
Page 54: ...54 75 2 2 1 o 2 2 2 10 1 2 3 Kastor 60...
Page 57: ...57 75 2 5 10 5 KSIL JK 2 6 10 20 445 555 4 2 5 3 SagaPK JK KSIL 2 3 Kastor 2 5 4 JK KSIL...
Page 59: ...59 75 2 8 2 9 Kastor Helo Helo 3 3 1 Kastor 2 38 12 20 3 2 17...
Page 60: ...60 75 3 3 2 3 4 2 2 3 5 2 50 60 3 6 2 4 4 1 Kastor Nokipois 4 2...
Page 61: ...61 75 8 4 3 2 6 7 4 4 Kastor Noki Pois 4 4 1 Saja JK 2 7 4 4 2 KSIL 9 1 2 3 4 3 5...
Page 62: ...62 75 3 5 115 130 3 3 3 2 2 2 10 80 C 3 2 3 2 3 5 2 2 10...
Page 71: ...71 75...
Page 72: ...72 75...
Page 73: ...73 75...
Page 74: ...74 75...
Page 75: ...75 75 16 11 2016...