INSTALLATION INSTRUCTIONS
© 2019 Kason Industries, Inc. IS-8600EZ-200 Rev 6 03/19
kasonind.com | 1.800.935.2766 | PAGE 16
8600EZ Power Drive
Single Doors and Bi-Parting Doors
Part Number: 8600*
Factory Presets:
The parameters that are preprogrammed from the factory:
Ramp-up/down speeds for door open and close
Factory Set
Main door size
35”
Main door auto-close times
5 seconds
Auto/Manual calibration speed
5 in/sec
Password Protected Drive Programming
The 8600Ez comes pre-programmed with all the parameters assigned. User adjustments have been minimized to make installation
simpler. Some parameters, if needed to be adjusted, may be done through technical sales support. Contact your local sales rep for
more information. 1-800-93-KASON.
Some parameters are password protected so the installation doesn’t change any factory presets. To access the password protected
menu, press “up/down” (See
Fig. 23
) to select “password” as a menu option. Press “enter”. The USER profile Password is: ENT,
DOWN, DOWN, ENT, ESC, ESC, ESC, ESC
User Profile Setup Menu
Close delay
0 max 240
Set the close delay timer, in seconds, that the door will remain fully open for before automatically
closing. A value of 0 disables the close delay timer.
Close over curr%
175 max 2000
During the first high-speed cycle after calibration, the system records the current usage over the profile
and uses this as a baseline for future closings. If on a future closing the current required is more than
this percentoid over the baseline, the door will detect a collision and re-open with all close timers
disabled.
Close decel
175 max 200
This is the percentoid during the door closing deceleration portion of the profile (just before the closing
crawl gap.)
Close clear
60 max 2000
Boost amount to apply to the above two parameters when clearing a previously detected collision.
This parameter can help prevent detection of new collisions when accelerating after clearing a
previous collision.
Open top speed
300 max 400
Target speed for high speed door movement on opening
Close top speed
250 max 400
Target speed for high speed movement of the door on closing
Dir Flip
1 or 0
Flips the direction of what is considered open and closed in the event that the motor is mounted in the
opposite orientation than normal
Dynamic brake
1 or 0
Enable (1)/ disable (0) dynamic braking action
Enter password
Allow to change to a different group