2 – 3 HP J SERIES FOUNTAIN
MANUAL
884168 / 2021.1.1
10
NOZZLE INSTALLATION INSTRUCTIONS
After removing the current nozzle and ensuring that the nozzle O-ring (F) is properly seated in its groove, twist the selected nozzle (E)
clockwise (as viewed from the top) so that the flanges in the nozzle lock into place on the top of the pump chamber by hand. Twist until
the nozzle flanges can move no further and are completely snug. Nozzles can be changed conveniently without removing the float or
using any tools�
Note: If it is difficult to twist the nozzle into place, dielectric grease (M) can be applied to the nozzle O-ring.
For Linden/Balsam Nozzles:
First ensure that the large Outlet nozzle is properly installed according to the above instructions� Insert the Balsam or Linden compo-
nents and thread into the insert at the top of the pump chamber, tightening everything by hand until snug� Do not over-tighten�
Twist until snug
OUTLET (6) nozzle
installed
Balsam
Linden
Fig. 18-20
Fig. 21-23
Back to Contents